Skip to main content
MS-DRG 277 · MDC 05 · Surgical

MS-DRG 277: Cardiac Defibrillator Implant without MCC

Compiled from CMS files by the QuickIntell RCM Editorial Team · Data effective · Method: reference methodology · Report a data correction

Data currency: IPPS Table 5 (MS-DRG weights): v44 FY2027 (final rule + CN3) (effective October 1, 2026); MS-DRG Definitions Manual: v44 (effective October 1, 2026). Next CMS release: FY2028 final rule (August 2027), effective October 1, 2027; an April 1 interim grouper update when CMS issues one for the IPPS Table 5 (MS-DRG weights); the FY2028 grouper, effective October 1, 2027 for the MS-DRG Definitions Manual.

Key facts for DRG 277

FY2027 relative weight
4.6889
Higher than 89% of all MS-DRGs
Change vs FY2026
+1.5%
FY2026 weight 4.6185
Geometric mean LOS
3.4 days
Arithmetic mean 4.2 days
MDC
05
Diseases and Disorders of the Circulatory System
Severity level
without MCC
National unadjusted operating payment
$32,109.59
Weight × $6,848.00 FY2027 standardized amount; capital adds $2,531.77
Transfer policy
Post-acute transfer DRG
Special-pay DRG

TL;DR

MS-DRG 277 is a surgical group in MDC 05 (Diseases and Disorders of the Circulatory System), at the lower of two severity levels (no MCC present). CMS assigns it a FY2027 relative weight of 4.6889 with a geometric mean length of stay of 3.4 days and an arithmetic mean of 4.2. Its weight moved up 1.5% from FY2026 (4.6185). That weight is higher than 89% of all MS-DRGs. Its weight sits 24.4% below DRG 276 (with MCC, 6.2034). The v44 Definitions Manual assigns it through 294 cardiac defibrillator implant (operating room procedures) codes.

What changed from FY2026 to FY2027

CMS recalibrates every MS-DRG weight annually from the prior year's MedPAR claims. For DRG 277 the FY2027 relative weight is 4.6889 against 4.6185 in FY2026, a rise of 1.52%.

FY2026 versus FY2027 payment factors for MS-DRG 277
MetricFY2026FY2027Change
Relative weight4.61854.6889+0.0704
Geometric mean LOS (days)3.33.4+0.1
Arithmetic mean LOS (days)4.14.2+0.1
Weights shown are the FY2027 final values after the 10% cap on year-over-year reductions where applicable.

CC and MCC family

DRG 277 shares its base definition with 1 other MS-DRG split by severity. The family's weights span 4.6889 to 6.2034, a 1.32× spread, which is the payment effect of documenting qualifying complications and comorbidities.

MS-DRGs in the same base group as DRG 277
DRGTitleFY2027 weightGMLOSNational operating payment
276Cardiac Defibrillator Implant with MCC or Carotid Sinus Neurostimulator6.20346.3$42,480.88
277Cardiac Defibrillator Implant without MCC4.68893.4$32,109.59

At the national rate, documenting the family's top severity level (DRG 276, $42,480.88) instead of its base level (DRG 277, $32,109.59) changes the operating payment by $10,371.30, the amount at stake when a qualifying secondary diagnosis goes undocumented. The figures are national operating amounts before the hospital-specific adjustments described below.

National unadjusted payment for DRG 277

Multiplying the FY2027 relative weight (4.6889) by the national rates in IPPS Tables 1A and 1D, as corrected by notice CMS-1849-CN3, gives the base amounts below. Across the CC/MCC family the operating amount spans $10,371.30.

FY2027 national unadjusted IPPS payment for MS-DRG 277
ComponentNational rateDRG 277
Operating (labor and nonlabor share)$4,519.68 + $2,328.32 = $6,848.00$32,109.59
Capital (federal rate)$539.95$2,531.77
Operating plus capital$34,641.36
Assumes the full annual update (the hospital submitted quality data and is a meaningful EHR user). A hospital with a reduced update starts from $31,105.18 to $31,858.50 for the operating portion of this DRG.

These are national, unadjusted figures, not what a given hospital is paid. The labor share is multiplied by the hospital's wage index (Table 1A applies when the wage index is above 1.0 and Table 1B otherwise), and teaching (IME), disproportionate share (DSH), outlier, transfer and new-technology add-on rules then change the amount for each stay. Because DRG 277 is on the post-acute transfer list, a qualifying early discharge to post-acute care is paid per diem against the 3.4-day geometric mean instead of the full amount. Use the figures to compare groups and to size a documentation finding, not to forecast a remittance; the DRG payment calculator applies a hospital's own wage index and teaching and DSH factors to DRG 277.

Grouper logic (v44 Definitions Manual)

The manual's split table for Cardiac Defibrillator Implant gives one row per combination of criteria and the MS-DRG it assigns. DRG 277 is the row where Cardiac Defibrillator Implant is Yes, MCC is No, Carotid Sinus Neurostimulator is No.

Split table for Cardiac Defibrillator Implant
Cardiac Defibrillator ImplantMCCCarotid Sinus NeurostimulatorDRG
YesYesnot checked276
not checkednot checkedYes276
YesNoNo277

Criteria stated in the manual

  • Without Carotid Sinus Neurostimulator

Cardiac Defibrillator Implant (Operating Room Procedures): 294 ICD-10-PCS code pairs in this DRG's assignment logic; the first 12 are shown.

Cardiac Defibrillator Implant (Operating Room Procedures) codes in the logic for DRG 277 (sample)
ICD-10-PCS codeDescription
02HK0KZ + 0JH609ZInsertion of Defibrillator Lead into Right Ventricle, Open Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Open Approach
02HK3KZ + 0JH609ZInsertion of Defibrillator Lead into Right Ventricle, Percutaneous Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Open Approach
02HK4KZ + 0JH609ZInsertion of Defibrillator Lead into Right Ventricle, Percutaneous Endoscopic Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Open Approach
02HL0KZ + 0JH609ZInsertion of Defibrillator Lead into Left Ventricle, Open Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Open Approach
02HL3KZ + 0JH609ZInsertion of Defibrillator Lead into Left Ventricle, Percutaneous Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Open Approach
02HL4KZ + 0JH609ZInsertion of Defibrillator Lead into Left Ventricle, Percutaneous Endoscopic Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Open Approach
02HK0KZ + 0JH639ZInsertion of Defibrillator Lead into Right Ventricle, Open Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
02HK3KZ + 0JH639ZInsertion of Defibrillator Lead into Right Ventricle, Percutaneous Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
02HK4KZ + 0JH639ZInsertion of Defibrillator Lead into Right Ventricle, Percutaneous Endoscopic Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
02HL0KZ + 0JH639ZInsertion of Defibrillator Lead into Left Ventricle, Open Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
02HL3KZ + 0JH639ZInsertion of Defibrillator Lead into Left Ventricle, Percutaneous Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach
02HL4KZ + 0JH639ZInsertion of Defibrillator Lead into Left Ventricle, Percutaneous Endoscopic Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach

Code editor, HAC and CC/MCC exclusion notes for DRG 277

Because this family splits by CC and MCC, a secondary diagnosis on the hospital-acquired condition list that is reported with a present-on-admission indicator of N or U does not count toward the severity level, and a CC or MCC excluded by the principal diagnosis does not count either. Check a secondary diagnosis and its CC exclusion before relying on it for the higher member.

Documentation and denial exposure

As a surgical DRG, assignment depends on a qualifying operating-room procedure being coded from the operative report; a missing or non-OR procedure code drops the stay into a medical DRG in MDC 05 with a lower weight. The inpatient claim reports that procedure in ICD-10-PCS, which NCCI does not edit; the surgeon's professional claim for the same operation carries CPT and HCPCS codes, and the NCCI pair checker for those professional codes shows whether two of them bundle. Because this family splits by severity, auditors target CC and MCC capture: each secondary diagnosis must be documented as present, monitored, evaluated or treated during the stay to survive a DRG-validation review. Typical inpatient denial codes for this group: CARC 16 (claim lacks information needed to group the stay), CARC 50 (the admission or procedure is judged not medically necessary), CARC 97 (a service is bundled into the DRG payment).

For teams evaluating QuickIntell software

Evaluate a documentation and coding workflow for DRG 277

Explore QuickCode for qualified coder review and documentation clarification, or QuickScribe for clinician-reviewed visit documentation. Confirm inpatient scope, the supported grouper version and reviewer responsibilities during evaluation. This public reference is not a production grouper and does not determine a claim's reimbursement.

Optional software evaluation, not payer support or help with an individual claim. For coverage or payment decisions, use the official sources on this page. Do not include patient information in a demo booking or inquiry.

Frequently asked questions — DRG 277

What is MS-DRG 277?

MS-DRG 277 is "Cardiac Defibrillator Implant without MCC", a surgical Medicare Severity Diagnosis-Related Group in MDC 05 (Diseases and Disorders of the Circulatory System). Medicare pays inpatient stays grouped here at the hospital's base rate multiplied by the DRG relative weight.

What is the FY2027 relative weight for DRG 277?

The FY2027 relative weight is 4.6889 (IPPS final rule Table 5, effective October 1, 2026). In FY2026 it was 4.6185, a change of +1.5%.

What is the Medicare base payment for MS-DRG 277?

$32,109.59 for operating costs plus $2,531.77 for capital, $34,641.36 together, at the FY2027 national rates: weight 4.6889 times the $6,848.00 operating standardized amount and the $539.95 capital rate (IPPS Tables 1A and 1D as corrected by CMS-1849-CN3). DRG 276 (with MCC) comes to $42,480.88 operating on the same basis. The hospital's wage index, IME, DSH, outlier and transfer adjustments change what a given stay is paid.

What is the average length of stay for DRG 277?

CMS reports a geometric mean length of stay of 3.4 days and an arithmetic mean of 4.2 days for FY2027. The geometric mean is used for transfer-payment calculations.

Which DRGs are in the same CC/MCC family as 277?

DRG 276 (with MCC, weight 6.2034, GMLOS 6.3 days). Together with DRG 277 the family spans 4.6889 to 6.2034, a 1.32x spread, so documented complications and comorbidities change payment materially.

What documentation supports the severity level of DRG 277?

DRG 277 is the lower level of a two-way MCC split: no secondary diagnosis on the CMS MCC list was coded, and CCs alone do not change the group. Review here looks for MCC-level conditions treated during the stay but not documented to the required specificity, such as acute respiratory failure, severe protein-calorie malnutrition or septic shock; a compliant query to the attending is the only way to move the stay to the MCC sibling.

Which codes group to DRG 277?

The v44 Definitions Manual lists 294 cardiac defibrillator implant (operating room procedures) codes for this group. Examples from the cardiac defibrillator implant (operating room procedures) list, 02HK4KZ + 0JH639Z (Insertion of Defibrillator Lead into Right Ventricle, Percutaneous Endoscopic Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach); 02HL0KZ + 0JH639Z (Insertion of Defibrillator Lead into Left Ventricle, Open Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach); 02HL3KZ + 0JH639Z (Insertion of Defibrillator Lead into Left Ventricle, Percutaneous Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach); 02HL4KZ + 0JH639Z (Insertion of Defibrillator Lead into Left Ventricle, Percutaneous Endoscopic Approach + Insertion of Cardiac Resynchronization Defibrillator Pulse Generator into Chest Subcutaneous Tissue and Fascia, Percutaneous Approach).

Is DRG 277 a post-acute transfer DRG?

Yes. CMS flags DRG 277 under the post-acute care transfer policy, so a discharge to a qualifying post-acute setting before the geometric mean length of stay is paid a per-diem amount rather than the full DRG payment. It is also a special-pay DRG.

CMS guidance

The Medicare Learning Network publication that CMS issues on this topic, cited by ICN and publication date:

Sources

Every figure on this page is taken from the CMS publications below, as released by the Centers for Medicare & Medicaid Services. Projection built 2026-11-16. Verify against the primary file before billing or contracting decisions. The reference methodology explains how each figure is computed from these files.

Disclaimer

This page is an operational reference compiled from the CMS IPPS FY2027 final rule (Table 5) and the v44 ICD-10 MS-DRG Definitions Manual. Relative weights are national factors; actual payment depends on each hospital's wage-adjusted base rate, add-ons, outliers and transfer adjustments. Nothing here is legal, clinical or billing advice; verify grouping against your encoder and the published CMS files.

Found a figure that does not match the CMS file? Report a data correction with the CMS file and the value you expected; the request reaches the editorial team through the contact form.