Skip to main content
MS-DRG 218 · MDC 05 · Surgical

MS-DRG 218: Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization without CC/MCC

Compiled from CMS files by the QuickIntell RCM Editorial Team · Data effective · Method: reference methodology · Report a data correction

Data currency: IPPS Table 5 (MS-DRG weights): v44 FY2027 (final rule + CN3) (effective October 1, 2026); MS-DRG Definitions Manual: v44 (effective October 1, 2026). Next CMS release: FY2028 final rule (August 2027), effective October 1, 2027; an April 1 interim grouper update when CMS issues one for the IPPS Table 5 (MS-DRG weights); the FY2028 grouper, effective October 1, 2027 for the MS-DRG Definitions Manual.

Key facts for DRG 218

FY2027 relative weight
6.8061
Higher than 96% of all MS-DRGs
Change vs FY2026
+3.5%
FY2026 weight 6.5753
Geometric mean LOS
3.9 days
Arithmetic mean 5.8 days
MDC
05
Diseases and Disorders of the Circulatory System
Severity level
without CC or MCC
National unadjusted operating payment
$46,608.17
Weight × $6,848.00 FY2027 standardized amount; capital adds $3,674.95
Transfer policy
Post-acute transfer DRG
Special-pay DRG

TL;DR

MS-DRG 218 is a surgical group in MDC 05 (Diseases and Disorders of the Circulatory System), at the lowest of three severity levels in its family. CMS assigns it a FY2027 relative weight of 6.8061 with a geometric mean length of stay of 3.9 days and an arithmetic mean of 5.8. Its weight moved up 3.5% from FY2026 (6.5753). That weight is higher than 96% of all MS-DRGs. Its weight sits 31.1% below DRG 216 (with MCC, 9.8832) and level with DRG 217 (with CC, 6.8061). The v44 Definitions Manual assigns it through 304 cardiac valve and other major cardiothoracic procedures (operating room procedures) codes and 75 cardiac catheterization (non-operating room procedures) codes.

What changed from FY2026 to FY2027

CMS recalibrates every MS-DRG weight annually from the prior year's MedPAR claims. For DRG 218 the FY2027 relative weight is 6.8061 against 6.5753 in FY2026, a rise of 3.51%, which exceeds the 2% threshold worth re-checking in contract models.

FY2026 versus FY2027 payment factors for MS-DRG 218
MetricFY2026FY2027Change
Relative weight6.57536.8061+0.2308
Geometric mean LOS (days)4.33.9-0.4
Arithmetic mean LOS (days)6.25.8-0.4
Weights shown are the FY2027 final values after the 10% cap on year-over-year reductions where applicable.

CC and MCC family

DRG 218 shares its base definition with 2 other MS-DRGs split by severity. The family's weights span 6.8061 to 9.8832, a 1.45× spread, which is the payment effect of documenting qualifying complications and comorbidities.

MS-DRGs in the same base group as DRG 218
DRGTitleFY2027 weightGMLOSNational operating payment
216Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with MCC9.883210.5$67,680.15
217Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization with CC6.80613.9$46,608.17
218Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization without CC/MCC6.80613.9$46,608.17

At the national rate, documenting the family's top severity level (DRG 216, $67,680.15) instead of its base level (DRG 218, $46,608.17) changes the operating payment by $21,071.98, the amount at stake when a qualifying secondary diagnosis goes undocumented. The figures are national operating amounts before the hospital-specific adjustments described below.

National unadjusted payment for DRG 218

Multiplying the FY2027 relative weight (6.8061) by the national rates in IPPS Tables 1A and 1D, as corrected by notice CMS-1849-CN3, gives the base amounts below. Across the CC/MCC family the operating amount spans $21,071.98.

FY2027 national unadjusted IPPS payment for MS-DRG 218
ComponentNational rateDRG 218
Operating (labor and nonlabor share)$4,519.68 + $2,328.32 = $6,848.00$46,608.17
Capital (federal rate)$539.95$3,674.95
Operating plus capital$50,283.12
Assumes the full annual update (the hospital submitted quality data and is a meaningful EHR user). A hospital with a reduced update starts from $45,150.24 to $46,243.71 for the operating portion of this DRG.

These are national, unadjusted figures, not what a given hospital is paid. The labor share is multiplied by the hospital's wage index (Table 1A applies when the wage index is above 1.0 and Table 1B otherwise), and teaching (IME), disproportionate share (DSH), outlier, transfer and new-technology add-on rules then change the amount for each stay. Because DRG 218 is on the post-acute transfer list, a qualifying early discharge to post-acute care is paid per diem against the 3.9-day geometric mean instead of the full amount. Use the figures to compare groups and to size a documentation finding, not to forecast a remittance; the DRG payment calculator applies a hospital's own wage index and teaching and DSH factors to DRG 218.

New for FY2027: codes that group to DRG 218

IPPS Tables 6A and 6B assign 5 new ICD-10-PCS codes to DRG 218 from October 1, 2026. Encoders and edit tables that still run the v43 code set reject these codes or group them elsewhere, so check them first when a FY2027 discharge in this DRG fails an edit. The FY2027 ICD-10 code-change report lists every addition and deletion with its CC level and MS-DRGs.

New FY2027 ICD-10-PCS codes that group to DRG 218
ICD-10-PCSDescriptionO.R.Effective
5A0527DAssistance with Circulatory Decompression using Impeller Pump, ContinuousYes2026-10-01
X2RH0GCReplacement of Pulmonary Valve using Size-Adjustable Synthetic Substitute, Open Approach, New Technology Group 12Yes2026-10-01
X2VJ3HCRestriction of Thoracic Aorta, Ascending and Arch using Branched Intraluminal Device, Integrated System with Innominate Branch, Percutaneous Approach, New Technology Group 12Yes2026-10-01
X2VW3JCRestriction of Thoracic Aorta, Descending using Branched Intraluminal Device, Integrated System Extension, Percutaneous Approach, New Technology Group 12Yes2026-10-01
X2VX0KCRestriction of Thoracic Aorta, Arch using Branched Intraluminal Device, with Conical Collar, Open Approach, New Technology Group 12Yes2026-10-01

Grouper logic (v44 Definitions Manual)

The manual's split table for Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization gives one row per combination of criteria and the MS-DRG it assigns. DRG 218 is the row where MCC is No, CC is No.

Split table for Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization
MCCCCDRG
Yesnot checked216
NoYes217
NoNo218

Cardiac Valve and Other Major Cardiothoracic Procedures (Operating Room Procedures): 304 ICD-10-PCS codes in this DRG's assignment logic; the first 12 are shown.

Cardiac Valve and Other Major Cardiothoracic Procedures (Operating Room Procedures) codes in the logic for DRG 218 (sample)
ICD-10-PCS codeDescription
024F07JCreation of Aortic Valve from Truncal Valve using Autologous Tissue Substitute, Open Approach
024F08JCreation of Aortic Valve from Truncal Valve using Zooplastic Tissue, Open Approach
024F0JJCreation of Aortic Valve from Truncal Valve using Synthetic Substitute, Open Approach
024F0KJCreation of Aortic Valve from Truncal Valve using Nonautologous Tissue Substitute, Open Approach
024G072Creation of Mitral Valve from Common Atrioventricular Valve using Autologous Tissue Substitute, Open Approach
024G082Creation of Mitral Valve from Common Atrioventricular Valve using Zooplastic Tissue, Open Approach
024G0J2Creation of Mitral Valve from Common Atrioventricular Valve using Synthetic Substitute, Open Approach
024G0K2Creation of Mitral Valve from Common Atrioventricular Valve using Nonautologous Tissue Substitute, Open Approach
024J072Creation of Tricuspid Valve from Common Atrioventricular Valve using Autologous Tissue Substitute, Open Approach
024J082Creation of Tricuspid Valve from Common Atrioventricular Valve using Zooplastic Tissue, Open Approach
024J0J2Creation of Tricuspid Valve from Common Atrioventricular Valve using Synthetic Substitute, Open Approach
024J0K2Creation of Tricuspid Valve from Common Atrioventricular Valve using Nonautologous Tissue Substitute, Open Approach

Cardiac Catheterization (Non-Operating Room Procedures): 75 ICD-10-PCS codes in this DRG's assignment logic; the first 12 are shown.

Cardiac Catheterization (Non-Operating Room Procedures) codes in the logic for DRG 218 (sample)
ICD-10-PCS codeDescription
4A020N6Measurement of Cardiac Sampling and Pressure, Right Heart, Open Approach
4A020N7Measurement of Cardiac Sampling and Pressure, Left Heart, Open Approach
4A020N8Measurement of Cardiac Sampling and Pressure, Bilateral, Open Approach
4A023FZMeasurement of Cardiac Rhythm, Percutaneous Approach
4A023N6Measurement of Cardiac Sampling and Pressure, Right Heart, Percutaneous Approach
4A023N7Measurement of Cardiac Sampling and Pressure, Left Heart, Percutaneous Approach
4A023N8Measurement of Cardiac Sampling and Pressure, Bilateral, Percutaneous Approach
4A027FZMeasurement of Cardiac Rhythm, Via Natural or Artificial Opening
4A027N6Measurement of Cardiac Sampling and Pressure, Right Heart, Via Natural or Artificial Opening
4A027N7Measurement of Cardiac Sampling and Pressure, Left Heart, Via Natural or Artificial Opening
4A027N8Measurement of Cardiac Sampling and Pressure, Bilateral, Via Natural or Artificial Opening
4A028FZMeasurement of Cardiac Rhythm, Via Natural or Artificial Opening Endoscopic

Code editor, HAC and CC/MCC exclusion notes for DRG 218

Because this family splits by CC and MCC, a secondary diagnosis on the hospital-acquired condition list that is reported with a present-on-admission indicator of N or U does not count toward the severity level, and a CC or MCC excluded by the principal diagnosis does not count either. Check a secondary diagnosis and its CC exclusion before relying on it for the higher member.

Documentation and denial exposure

As a surgical DRG, assignment depends on a qualifying operating-room procedure being coded from the operative report; a missing or non-OR procedure code drops the stay into a medical DRG in MDC 05 with a lower weight. The inpatient claim reports that procedure in ICD-10-PCS, which NCCI does not edit; the surgeon's professional claim for the same operation carries CPT and HCPCS codes, and the NCCI pair checker for those professional codes shows whether two of them bundle. Because this family splits by severity, auditors target CC and MCC capture: each secondary diagnosis must be documented as present, monitored, evaluated or treated during the stay to survive a DRG-validation review. Typical inpatient denial codes for this group: CARC 16 (claim lacks information needed to group the stay), CARC 50 (the admission or procedure is judged not medically necessary), CARC 97 (a service is bundled into the DRG payment).

For teams evaluating QuickIntell software

Evaluate a documentation and coding workflow for DRG 218

Explore QuickCode for qualified coder review and documentation clarification, or QuickScribe for clinician-reviewed visit documentation. Confirm inpatient scope, the supported grouper version and reviewer responsibilities during evaluation. This public reference is not a production grouper and does not determine a claim's reimbursement.

Optional software evaluation, not payer support or help with an individual claim. For coverage or payment decisions, use the official sources on this page. Do not include patient information in a demo booking or inquiry.

Frequently asked questions — DRG 218

What is MS-DRG 218?

MS-DRG 218 is "Cardiac Valve and Other Major Cardiothoracic Procedures with Cardiac Catheterization without CC/MCC", a surgical Medicare Severity Diagnosis-Related Group in MDC 05 (Diseases and Disorders of the Circulatory System). Medicare pays inpatient stays grouped here at the hospital's base rate multiplied by the DRG relative weight.

What is the FY2027 relative weight for DRG 218?

The FY2027 relative weight is 6.8061 (IPPS final rule Table 5, effective October 1, 2026). In FY2026 it was 6.5753, a change of +3.5%.

What is the Medicare base payment for MS-DRG 218?

$46,608.17 for operating costs plus $3,674.95 for capital, $50,283.12 together, at the FY2027 national rates: weight 6.8061 times the $6,848.00 operating standardized amount and the $539.95 capital rate (IPPS Tables 1A and 1D as corrected by CMS-1849-CN3). DRG 216 (with MCC) comes to $67,680.15 operating on the same basis. DRG 217 (with CC) comes to $46,608.17 operating on the same basis. The hospital's wage index, IME, DSH, outlier and transfer adjustments change what a given stay is paid.

What is the average length of stay for DRG 218?

CMS reports a geometric mean length of stay of 3.9 days and an arithmetic mean of 5.8 days for FY2027. The geometric mean is used for transfer-payment calculations.

Which DRGs are in the same CC/MCC family as 218?

DRG 216 (with MCC, weight 9.8832, GMLOS 10.5 days); DRG 217 (with CC, weight 6.8061, GMLOS 3.9 days). Together with DRG 218 the family spans 6.8061 to 9.8832, a 1.45x spread, so documented complications and comorbidities change payment materially.

What documentation supports the severity level of DRG 218?

DRG 218 is the base-severity assignment: no secondary diagnosis on the CC or MCC lists was coded, or the only ones present are excluded for this principal diagnosis. Revenue-integrity review here looks for undercapture, meaning conditions treated during the stay (electrolyte disorders, specified anemia, acute blood loss, pressure injuries present on admission) that were never documented to the specificity the lists require. A compliant query to the attending, not a coder assumption, is the only way to move a stay to the CC or MCC sibling.

Which codes group to DRG 218?

The v44 Definitions Manual lists 304 cardiac valve and other major cardiothoracic procedures (operating room procedures) codes and 75 cardiac catheterization (non-operating room procedures) codes for this group. Examples from the cardiac valve and other major cardiothoracic procedures (operating room procedures) list, 024G0J2 (Creation of Mitral Valve from Common Atrioventricular Valve using Synthetic Substitute, Open Approach); 024G0K2 (Creation of Mitral Valve from Common Atrioventricular Valve using Nonautologous Tissue Substitute, Open Approach); and from the cardiac catheterization (non-operating room procedures) list, 4A023N8 (Measurement of Cardiac Sampling and Pressure, Bilateral, Percutaneous Approach); 4A027FZ (Measurement of Cardiac Rhythm, Via Natural or Artificial Opening).

Is DRG 218 a post-acute transfer DRG?

Yes. CMS flags DRG 218 under the post-acute care transfer policy, so a discharge to a qualifying post-acute setting before the geometric mean length of stay is paid a per-diem amount rather than the full DRG payment. It is also a special-pay DRG.

Sources

Every figure on this page is taken from the CMS publications below, as released by the Centers for Medicare & Medicaid Services. Projection built 2026-11-16. Verify against the primary file before billing or contracting decisions. The reference methodology explains how each figure is computed from these files.

Disclaimer

This page is an operational reference compiled from the CMS IPPS FY2027 final rule (Table 5) and the v44 ICD-10 MS-DRG Definitions Manual. Relative weights are national factors; actual payment depends on each hospital's wage-adjusted base rate, add-ons, outliers and transfer adjustments. Nothing here is legal, clinical or billing advice; verify grouping against your encoder and the published CMS files.

Found a figure that does not match the CMS file? Report a data correction with the CMS file and the value you expected; the request reaches the editorial team through the contact form.