Skip to main content
MS-DRG 211 · MDC 05 · Surgical

MS-DRG 211: Cardiac Pacemaker Revision or Device Replacement without MCC

Compiled from CMS files by the QuickIntell RCM Editorial Team · Data effective · Method: reference methodology · Report a data correction

Data currency: IPPS Table 5 (MS-DRG weights): v44 FY2027 (final rule + CN3) (effective October 1, 2026); MS-DRG Definitions Manual: v44 (effective October 1, 2026). Next CMS release: FY2028 final rule (August 2027), effective October 1, 2027; an April 1 interim grouper update when CMS issues one for the IPPS Table 5 (MS-DRG weights); the FY2028 grouper, effective October 1, 2027 for the MS-DRG Definitions Manual.

Key facts for DRG 211

FY2027 relative weight
1.8091
Higher than 57% of all MS-DRGs
Change vs FY2026
New DRG
No FY2026 weight
Geometric mean LOS
2.6 days
Arithmetic mean 3.3 days
MDC
05
Diseases and Disorders of the Circulatory System
Severity level
without MCC
National unadjusted operating payment
$12,388.72
Weight × $6,848.00 FY2027 standardized amount; capital adds $976.82
Transfer policy
Post-acute transfer DRG

TL;DR

MS-DRG 211 is a surgical group in MDC 05 (Diseases and Disorders of the Circulatory System), at the lower of two severity levels (no MCC present). CMS assigns it a FY2027 relative weight of 1.8091 with a geometric mean length of stay of 2.6 days and an arithmetic mean of 3.3. It is new for FY2027, so there is no prior-year weight to compare. That weight is higher than 57% of all MS-DRGs. Its weight sits 44.6% below DRG 210 (with MCC, 3.2640). The v44 Definitions Manual assigns it through 27 cardiac pacemaker revision or device replacement (operating room procedures) codes and 60 cardiac pacemaker revision or device replacement (non-operating room procedures) codes.

What changed from FY2026 to FY2027

DRG 211 is new in the v44 grouper effective October 1, 2026, so there is no FY2026 weight to compare. Review the FY2027 final rule Table 6 series for the code moves that created it and confirm that your encoder and contract modeling have loaded v44. The weight-change report lists it with the other new groups.

CC and MCC family

DRG 211 shares its base definition with 1 other MS-DRG split by severity. The family's weights span 1.8091 to 3.2640, a 1.80× spread, which is the payment effect of documenting qualifying complications and comorbidities.

MS-DRGs in the same base group as DRG 211
DRGTitleFY2027 weightGMLOSNational operating payment
210Cardiac Pacemaker Revision or Device Replacement with MCC3.26405.4$22,351.87
211Cardiac Pacemaker Revision or Device Replacement without MCC1.80912.6$12,388.72

At the national rate, documenting the family's top severity level (DRG 210, $22,351.87) instead of its base level (DRG 211, $12,388.72) changes the operating payment by $9,963.16, the amount at stake when a qualifying secondary diagnosis goes undocumented. The figures are national operating amounts before the hospital-specific adjustments described below.

National unadjusted payment for DRG 211

Multiplying the FY2027 relative weight (1.8091) by the national rates in IPPS Tables 1A and 1D, as corrected by notice CMS-1849-CN3, gives the base amounts below. Across the CC/MCC family the operating amount spans $9,963.16.

FY2027 national unadjusted IPPS payment for MS-DRG 211
ComponentNational rateDRG 211
Operating (labor and nonlabor share)$4,519.68 + $2,328.32 = $6,848.00$12,388.72
Capital (federal rate)$539.95$976.82
Operating plus capital$13,365.54
Assumes the full annual update (the hospital submitted quality data and is a meaningful EHR user). A hospital with a reduced update starts from $12,001.19 to $12,291.84 for the operating portion of this DRG.

These are national, unadjusted figures, not what a given hospital is paid. The labor share is multiplied by the hospital's wage index (Table 1A applies when the wage index is above 1.0 and Table 1B otherwise), and teaching (IME), disproportionate share (DSH), outlier, transfer and new-technology add-on rules then change the amount for each stay. Because DRG 211 is on the post-acute transfer list, a qualifying early discharge to post-acute care is paid per diem against the 2.6-day geometric mean instead of the full amount. Use the figures to compare groups and to size a documentation finding, not to forecast a remittance; the DRG payment calculator applies a hospital's own wage index and teaching and DSH factors to DRG 211.

New for FY2027: codes that group to DRG 211

IPPS Tables 6A and 6B assign 3 new ICD-10-PCS codes to DRG 211 from October 1, 2026. Encoders and edit tables that still run the v43 code set reject these codes or group them elsewhere, so check them first when a FY2027 discharge in this DRG fails an edit. The FY2027 ICD-10 code-change report lists every addition and deletion with its CC level and MS-DRGs.

New FY2027 ICD-10-PCS codes that group to DRG 211
ICD-10-PCSDescriptionO.R.Effective
02HM3JZInsertion of Pacemaker Lead into Ventricular Septum, Percutaneous ApproachNo2026-04-01
02HM3MZInsertion of Cardiac Lead into Ventricular Septum, Percutaneous ApproachNo2026-04-01
02HM3YZInsertion of Other Device into Ventricular Septum, Percutaneous ApproachYes2026-04-01

Grouper logic (v44 Definitions Manual)

The manual's split table for Cardiac Pacemaker Revision or Device Replacement gives one row per combination of criteria and the MS-DRG it assigns. DRG 211 is the row where MCC is No.

Split table for Cardiac Pacemaker Revision or Device Replacement
MCCDRG
Yes210
No211

Cardiac Pacemaker Revision or Device Replacement (Operating Room Procedures): 27 ICD-10-PCS codes in this DRG's assignment logic; the first 12 are shown.

Cardiac Pacemaker Revision or Device Replacement (Operating Room Procedures) codes in the logic for DRG 211 (sample)
ICD-10-PCS codeDescription
02HK00ZInsertion of Pressure Sensor Monitoring Device into Right Ventricle, Open Approach
02HK02ZInsertion of Monitoring Device into Right Ventricle, Open Approach
02HK0YZInsertion of Other Device into Right Ventricle, Open Approach
02HK3YZInsertion of Other Device into Right Ventricle, Percutaneous Approach
02HK40ZInsertion of Pressure Sensor Monitoring Device into Right Ventricle, Percutaneous Endoscopic Approach
02HK42ZInsertion of Monitoring Device into Right Ventricle, Percutaneous Endoscopic Approach
02HK4YZInsertion of Other Device into Right Ventricle, Percutaneous Endoscopic Approach
02HM3YZInsertion of Other Device into Ventricular Septum, Percutaneous Approach
02PA0MZRemoval of Cardiac Lead from Heart, Open Approach
02PA3MZRemoval of Cardiac Lead from Heart, Percutaneous Approach
02PA4MZRemoval of Cardiac Lead from Heart, Percutaneous Endoscopic Approach
02WA0MZRevision of Cardiac Lead in Heart, Open Approach

Cardiac Pacemaker Revision or Device Replacement (Non-Operating Room Procedures): 60 ICD-10-PCS codes in this DRG's assignment logic; the first 12 are shown.

Cardiac Pacemaker Revision or Device Replacement (Non-Operating Room Procedures) codes in the logic for DRG 211 (sample)
ICD-10-PCS codeDescription
02H40JZInsertion of Pacemaker Lead into Coronary Vein, Open Approach
02H40MZInsertion of Cardiac Lead into Coronary Vein, Open Approach
02H43JZInsertion of Pacemaker Lead into Coronary Vein, Percutaneous Approach
02H43MZInsertion of Cardiac Lead into Coronary Vein, Percutaneous Approach
02H44JZInsertion of Pacemaker Lead into Coronary Vein, Percutaneous Endoscopic Approach
02H44MZInsertion of Cardiac Lead into Coronary Vein, Percutaneous Endoscopic Approach
02H60JZInsertion of Pacemaker Lead into Right Atrium, Open Approach
02H60MZInsertion of Cardiac Lead into Right Atrium, Open Approach
02H63JZInsertion of Pacemaker Lead into Right Atrium, Percutaneous Approach
02H63MZInsertion of Cardiac Lead into Right Atrium, Percutaneous Approach
02H64JZInsertion of Pacemaker Lead into Right Atrium, Percutaneous Endoscopic Approach
02H64MZInsertion of Cardiac Lead into Right Atrium, Percutaneous Endoscopic Approach

Code editor, HAC and CC/MCC exclusion notes for DRG 211

DRG 211 is new in the v44 grouper. Codes that grouped to MS-DRGs CMS deleted for FY2027 now group here: DRG 259 Cardiac Pacemaker Device Replacement without MCC (all 21 of its codes); DRG 261 Cardiac Pacemaker Revision Except Device Replacement with CC (all 66 of its codes); DRG 262 Cardiac Pacemaker Revision Except Device Replacement without CC/MCC (all 66 of its codes). The FY2026 weights of those groups are on the MDC page under the retired MS-DRGs.

56 procedure codes in this DRG's logic are on the procedure list of HAC 13 (Surgical Site Infection (SSI) Following Cardiac Implantable Electronic Device (CIED) Procedures), for example 02H40JZ. When the condition that category tracks is coded as a secondary diagnosis with a present-on-admission indicator of N or U after one of these procedures, the grouper does not count it as a CC or MCC. The FY2027 HAC list gives the diagnoses and procedures of each category.

Documentation and denial exposure

As a surgical DRG, assignment depends on a qualifying operating-room procedure being coded from the operative report; a missing or non-OR procedure code drops the stay into a medical DRG in MDC 05 with a lower weight. The inpatient claim reports that procedure in ICD-10-PCS, which NCCI does not edit; the surgeon's professional claim for the same operation carries CPT and HCPCS codes, and the NCCI pair checker for those professional codes shows whether two of them bundle. Because this family splits by severity, auditors target CC and MCC capture: each secondary diagnosis must be documented as present, monitored, evaluated or treated during the stay to survive a DRG-validation review. Typical inpatient denial codes for this group: CARC 16 (claim lacks information needed to group the stay), CARC 50 (the admission or procedure is judged not medically necessary), CARC 97 (a service is bundled into the DRG payment).

For teams evaluating QuickIntell software

Evaluate a documentation and coding workflow for DRG 211

Explore QuickCode for qualified coder review and documentation clarification, or QuickScribe for clinician-reviewed visit documentation. Confirm inpatient scope, the supported grouper version and reviewer responsibilities during evaluation. This public reference is not a production grouper and does not determine a claim's reimbursement.

Optional software evaluation, not payer support or help with an individual claim. For coverage or payment decisions, use the official sources on this page. Do not include patient information in a demo booking or inquiry.

Frequently asked questions — DRG 211

What is MS-DRG 211?

MS-DRG 211 is "Cardiac Pacemaker Revision or Device Replacement without MCC", a surgical Medicare Severity Diagnosis-Related Group in MDC 05 (Diseases and Disorders of the Circulatory System). Medicare pays inpatient stays grouped here at the hospital's base rate multiplied by the DRG relative weight.

What is the FY2027 relative weight for DRG 211?

The FY2027 relative weight is 1.8091 (IPPS final rule Table 5, effective October 1, 2026). The DRG is new for FY2027.

What is the Medicare base payment for MS-DRG 211?

$12,388.72 for operating costs plus $976.82 for capital, $13,365.54 together, at the FY2027 national rates: weight 1.8091 times the $6,848.00 operating standardized amount and the $539.95 capital rate (IPPS Tables 1A and 1D as corrected by CMS-1849-CN3). DRG 210 (with MCC) comes to $22,351.87 operating on the same basis. The hospital's wage index, IME, DSH, outlier and transfer adjustments change what a given stay is paid.

What is the average length of stay for DRG 211?

CMS reports a geometric mean length of stay of 2.6 days and an arithmetic mean of 3.3 days for FY2027. The geometric mean is used for transfer-payment calculations.

Which DRGs are in the same CC/MCC family as 211?

DRG 210 (with MCC, weight 3.2640, GMLOS 5.4 days). Together with DRG 211 the family spans 1.8091 to 3.2640, a 1.80x spread, so documented complications and comorbidities change payment materially.

What documentation supports the severity level of DRG 211?

DRG 211 is the lower level of a two-way MCC split: no secondary diagnosis on the CMS MCC list was coded, and CCs alone do not change the group. Review here looks for MCC-level conditions treated during the stay but not documented to the required specificity, such as acute respiratory failure, severe protein-calorie malnutrition or septic shock; a compliant query to the attending is the only way to move the stay to the MCC sibling.

Which codes group to DRG 211?

The v44 Definitions Manual lists 27 cardiac pacemaker revision or device replacement (operating room procedures) codes and 60 cardiac pacemaker revision or device replacement (non-operating room procedures) codes for this group. Examples from the cardiac pacemaker revision or device replacement (operating room procedures) list, 02HK00Z (Insertion of Pressure Sensor Monitoring Device into Right Ventricle, Open Approach); 02HK02Z (Insertion of Monitoring Device into Right Ventricle, Open Approach); and from the cardiac pacemaker revision or device replacement (non-operating room procedures) list, 02H40JZ (Insertion of Pacemaker Lead into Coronary Vein, Open Approach); 02H40MZ (Insertion of Cardiac Lead into Coronary Vein, Open Approach).

Is DRG 211 a post-acute transfer DRG?

Yes. CMS flags DRG 211 under the post-acute care transfer policy, so a discharge to a qualifying post-acute setting before the geometric mean length of stay is paid a per-diem amount rather than the full DRG payment.

CMS guidance

The Medicare Learning Network publication that CMS issues on this topic, cited by ICN and publication date:

Sources

Every figure on this page is taken from the CMS publications below, as released by the Centers for Medicare & Medicaid Services. Projection built 2026-11-16. Verify against the primary file before billing or contracting decisions. The reference methodology explains how each figure is computed from these files.

Disclaimer

This page is an operational reference compiled from the CMS IPPS FY2027 final rule (Table 5) and the v44 ICD-10 MS-DRG Definitions Manual. Relative weights are national factors; actual payment depends on each hospital's wage-adjusted base rate, add-ons, outliers and transfer adjustments. Nothing here is legal, clinical or billing advice; verify grouping against your encoder and the published CMS files.

Found a figure that does not match the CMS file? Report a data correction with the CMS file and the value you expected; the request reaches the editorial team through the contact form.