LCD L36831: Visual Electrophysiology Testing

LCD L36831, Visual Electrophysiology Testing, is the Local Coverage Determination that Wellpoint Federal applies to claims from 13 states (CT, DN, IL, MA, ME, MN, NH, NY and others), effective 2026-04-01 and first in force 2017-03-16. The policy text runs 825 words, and its billing and coding article A57060 lists 655 ICD-10-CM codes that support medical necessity for 6 procedure codes. 1 other contractor publish a policy with the same title, so the criteria that apply depend on where the service is furnished.

QuickIntell editorial content · Legacy registry date · Review not verified

Data effective
Data currency: Medicare Coverage Database LCD export release of September 24, 2026 (effective September 20, 2026). Next CMS release: weekly (Thursdays) for the MCD.
Contractor
Wellpoint Federal
States and territories
13
CT DN IL MA ME MN NH NY QN RI UN VT WI
Revision effective
2026-04-01
Original effective
2017-03-16
Policy text
825 words
Covered ICD-10 codes (articles)
655

Where this LCD applies

Each contract number is a jurisdiction on the remittance; the policy binds claims processed under these contracts and no others.

Contracts that apply LCD L36831
ContractContractorTypeStates
06101Wellpoint FederalMAC - Part AIL
06201Wellpoint FederalMAC - Part AMN
06301Wellpoint FederalMAC - Part AWI
06102Wellpoint FederalMAC - Part BIL
06202Wellpoint FederalMAC - Part BMN
06302Wellpoint FederalMAC - Part BWI
13101Wellpoint FederalA and B and HHH MACCT
13201Wellpoint FederalA and B and HHH MACNY
13102Wellpoint FederalA and B and HHH MACCT
13202Wellpoint FederalA and B and HHH MACDN
13282Wellpoint FederalA and B and HHH MACUN
13292Wellpoint FederalA and B and HHH MACQN
14411Wellpoint FederalA and B and HHH MACRI
14211Wellpoint FederalA and B and HHH MACMA
14311Wellpoint FederalA and B and HHH MACNH
14511Wellpoint FederalA and B and HHH MACVT
14111Wellpoint FederalA and B and HHH MACME
14112Wellpoint FederalA and B and HHH MACME
14212Wellpoint FederalA and B and HHH MACMA
14312Wellpoint FederalA and B and HHH MACNH
14512Wellpoint FederalA and B and HHH MACVT
14412Wellpoint FederalA and B and HHH MACRI

Billing and coding: diagnoses and procedure codes

Since 2019 the codes live in the companion article rather than the LCD. Billing and Coding A57060 (Billing and Coding: Visual Electrophysiology Testing) carries the diagnosis and procedure lists the contractor loads as the claims edit. CPT codes are shown as bare numbers because the descriptors are licensed by the AMA; HCPCS Level II descriptors are public and shown.

A57060: Billing and Coding: Visual Electrophysiology Testing (Billing and Coding, effective 2026-04-01)

Covered ICD-10-CM codes
655
2 groups
Non-covered ICD-10-CM codes
0
Procedure codes listed
6
Full article
cms.gov record
First 24 covered ICD-10-CM codes in A57060
ICD-10-CMDescription (FY2027)
A18.53—
B50.0—
B50.8—
B50.9—
D18.09—
E08.311—
E08.319—
E08.3211—
E08.3212—
E08.3213—
E08.3291—
E08.3292—
E08.3293—
E08.3311—
E08.3312—
E08.3313—
E08.3391—
E08.3392—
E08.3393—
E08.3411—
E08.3412—
E08.3413—
E08.3491—
E08.3492—

Procedure codes: 0333T, 0464T, 0509T, 92273, 92274, 95930.

Coverage indications, limitations and medical necessity

Abstract

VEP/VER - The visual evoked response (VER) and visual evoked potential (VEP) evaluate the visual nervous system pathways from the eyes to the occipital cortex of the brain. By measuring the function of the entire visual pathway, it helps to separate eye disease from central nervous system defects. VER/VEP involves stimulation of the retina and optic nerve with a shifting checkerboard pattern or flash method. This external visual stimulus causes measurable electrical activity in neurons within the visual pathways. The VER is recorded by electroencephalography electrodes located over the occiput producing a characteristic waveform. Abnormalities may be seen in a variety of pathologic processes involving the optic nerve and its radiations. Pattern-shift VER is a highly sensitive means of documenting lesions in the visual system.

ERG - The full field electroretinogram (ERG) is used to detect loss of retinal function or distinguish between retinal and optic nerve lesions. ERG measures the electrical activity generated by neural and non-neuronal cells in the retina in response to a light stimulus. ERGs are usually obtained using electrodes embedded in a corneal contact lens, or a thin wire inside the lower eyelid, which measure a summation of retinal electrical activity at the corneal surface. The International Society for Clinical Electrophysiology of Vision (ISCEV) introduced minimum standards for the ERG in 1989. The ERG helps to distinguish retinal degeneration and dystrophies. Multi-focal electroretinography (mfERG) is a higher resolution form of ERG, enabling assessment of ERG activity in small areas of the retina. Pattern ERG (PERG) to assess retinal ganglion cell (RGC) function in glaucoma is being investigated.

Indications of Coverage

Visual Evoked Potentials or Responses (VEPs/VERs)

• Confirm diagnosis of multiple sclerosis when clinical criteria are inconclusive

• Evaluate diseases of the optic nerve, such as:

• Optic neuritis

• Ischemic optic neuropathy

• Toxic amblyopias

• Nutritional amblyopias

• Neoplasms compressing the anterior visual pathways

• Optic nerve injury or atrophy

• Malingering/functional vision loss (to rule out)

• Monitor the visual system during optic nerve (or related) surgery (monitoring of short-latency evoked potential studies).

Electroretinography (ERG)

• To diagnose loss of retinal function or distinguish between retinal lesions and optic nerve lesions:

• Toxic retinopathies, including those caused by intraocular metallic foreign bodies and Vigabatrin

• Diabetic retinopathy

• Ischemic retinopathies including central retinal vein occlusion (CRVO), branch vein occlusion (BVO), and sickle cell retinopathy

• Autoimmune retinopathies such as Cancer Associated Retinopathy (CAR), Melanoma Associated Retinopathy (MAR), and Acute Zonal Occult Outer Retinopathy (AZOOR)

• Retinal detachment

• Assessment of retinal function after trauma, especially in vitreous hemorrhage, dense cataracts, and other conditions where the fundus cannot be visualized photoreceptors; absent b-wave indicates abnormality in the bipolar cell region.

• Retinitis pigmentosa and related hereditary degenerations

• Retinitis punctata albescens

• Leber's congenital amaurosis

• Choroideremia

• Gyrate atrophy of the retina and choroid

• Goldman-Favre syndrome

• Congenital stationary night blindness

• X-linked juvenile retinoschisis

• Achromatopsia

• Cone dystrophy

• Disorders mimicking retinitis pigmentosa

• Usher Syndrome

• To detect chloroquine (Aralen) and hydroxychloroquine (Plaquenil) toxicity (mfERG) per AAO guidelines (10).

VEP/ERG in Glaucoma

A 2011 report by the AAO on “Assessment of Visual Function in Glaucoma” noted that while VEP and ERG, as objective measures of visual function, provided testing free of patient input, issues prevent their adoption for glaucoma management (1). It concluded that advances in technology have yet to produce definitive guidance on the diagnosis of glaucoma or its progression over time and that further research on an objective measure of visual function is needed.

Since then several studies (2-5) have investigated the use of VEP and ERG technology to differentiate between normal healthy eyes and eyes with early to advanced visual field loss resulting from glaucoma. The authors indicated that VEP and ERG may allow earlier diagnosis of glaucoma. However, NGS has determined that without larger studies, AAO’s 2011 conclusion, that these technologies have yet to produce definitive guidance on the diagnosis of glaucoma or its progression over time, remains. This was also the conclusion of a 2013 study which prospectively monitored progressive changes of RGC function in early glaucoma using PERG (6). The authors concluded that further follow-up is required to determine whether PERG losses are predictors of future visual field loss.

Neither of the 2015 AAO Preferred Practice Guidelines, “Primary Open-Angle Glaucoma Suspect” or “Primary Open-Angle Glaucoma,” mention VEP or ERG as diagnostic tools (7,8). Also, the UpToDate review on “Open-angle glaucoma: Epidemiology, clinical presentation, and diagnosis,” likewise omits reference to either test (9).

There remain no verified guidelines for normal vs abnormal that would be easily applicable to an individual patient. NGS, therefore, considers the use of VEP or ERG for either glaucoma diagnosis or management investigational.

Limitations

Testing shall be performed by physicians who have evidence of knowledge, training, and expertise to perform and interpret these tests. This training and expertise must have been acquired within the framework of an accredited school, residency or fellowship program.

Summary of evidence (opening)

N/A

the full summary and analysis of evidence are in the CMS record.

Dates, lineage and related policies

Original determination effective
2017-03-16
Current revision effective
2026-04-01
Last reviewed by the contractor
2016-12-16
MCD version
35

Other related documents: A55475 (Response to Comments).

Using this policy on a claim

Match the documented indication to the covered indications above before the service is scheduled, carry a diagnosis from the article's covered list on the claim line, and keep the elements the documentation section asks for in the record, because the contractor can request it later through medical review. A denial under this policy arrives as CARC 50 with remark N115; the LCD lookup guide walks through the appeal path and the Advance Beneficiary Notice rules, and the Wellpoint Federal hub lists every other active policy from the same contractor.

The same policy title at other contractors

Contractors often adopt each other's policies and then revise them separately, so the criteria and the diagnosis lists drift apart. The topic comparison lines up every version.

Frequently asked questions

What does LCD L36831 cover?

VEP/VER - The visual evoked response (VER) and visual evoked potential (VEP) evaluate the visual nervous system pathways from the eyes to the occipital cortex of the brain. By measuring the function of the entire visual pathway, it helps to separate eye disease from central nervous system defects. VER/VEP involves stimulation of the retina and optic nerve with a shifting checkerboard pattern or flash method. This… The full indications and limitations are reproduced on this page from the CMS Medicare Coverage Database export of September 24, 2026.

Which states does LCD L36831 apply to?

Wellpoint Federal applies it to Medicare claims in CT, DN, IL, MA, ME, MN, NH, NY, QN, RI, UN, VT, WI. A Local Coverage Determination binds only the contractor that wrote it; the same service in another jurisdiction is judged under that contractor's own policy or, where none exists, claim by claim.

Which diagnosis codes support medical necessity under LCD L36831?

The companion billing and coding article A57060 lists 655 ICD-10-CM codes in 2 groups that support medical necessity; the first 24 appear on this page and the complete list is in the article on cms.gov.

How do I appeal a denial under LCD L36831?

The remittance carries claim adjustment reason code 50 with remark code N115, naming the LCD. Compare the documented indication with the policy's covered indications and the article's diagnosis list, then file a redetermination within 120 days with the record attached; if the service genuinely falls outside the policy, the patient can be billed only when a valid Advance Beneficiary Notice was obtained before the service.

Sources

Every figure on this page is taken from the CMS publications below, as released by the Centers for Medicare & Medicaid Services. Projection built 2026-10-02. Verify against the primary file before billing or contracting decisions.

Disclaimer

The policy text and code lists are reproduced from the CMS Medicare Coverage Database export as an operational reference. Verify against the current LCD and article on cms.gov before billing; coverage depends on the full record and the contractor. Not legal, clinical or billing advice.