LCD L34061: Scanning Computerized Ophthalmic Diagnostic Imaging (SCODI)

LCD L34061, Scanning Computerized Ophthalmic Diagnostic Imaging (SCODI), is the Local Coverage Determination that CGS Administrators, LLC applies to claims from 2 states (KY, OH), effective 2026-08-06 and first in force 2015-10-01. The policy text runs 1,587 words, and its billing and coding article A56692 lists 720 ICD-10-CM codes that support medical necessity for 3 procedure codes. 5 other contractor versions share this title, so the criteria depend on where the service is furnished. Counting every linked billing and coding article, this one lists 720 covered ICD-10-CM codes: 5 fewer codes than L33751 (First Coast Service Options, Inc., 725 codes, revised 2019-11-28) and 5 fewer codes than L35038 (Novitas Solutions, Inc., 725 codes, revised 2019-10-31).

Compiled from CMS files by the QuickIntell RCM Editorial Team · Data effective · Method: reference methodology · Report a data correction

Data currency: Medicare Coverage Database LCD export: MCD release November 12, 2026 (effective November 8, 2026); Medicare Coverage Database billing and coding articles: MCD release November 12, 2026 (effective November 8, 2026). Next CMS release: weekly, every Thursday.

Contractor
CGS Administrators, LLC
States and territories
2
KY OH
Revision effective
2026-08-06
Original effective
2015-10-01
Policy text
1,587 words
Covered ICD-10 codes (articles)
720

Where this LCD applies

Each contract number is a jurisdiction on the remittance; the policy binds claims processed under these contracts and no others.

Contracts that apply LCD L34061
ContractContractorTypeStates
15102CGS Administrators, LLCMAC - Part BKY
15202CGS Administrators, LLCMAC - Part BOH
15101CGS Administrators, LLCMAC - Part AKY
15201CGS Administrators, LLCMAC - Part AOH

Billing and coding article A56692: diagnoses and procedure codes

Since 2019 the codes live in the companion article rather than the LCD. Billing and Coding A56692 (Billing and Coding: Scanning Computerized Ophthalmic Diagnostic Imaging (SCODI)) carries the diagnosis and procedure lists the contractor loads as the claims edit. CPT codes are shown as bare numbers because the descriptors are licensed by the AMA; HCPCS Level II descriptors are public and shown. Each article below opens its complete covered and non-covered ICD-10-CM lists, by group and with the contractor's group instructions, and the LCD code lookup answers whether one diagnosis is covered for one procedure code in a given state.

Coverage is only half of the claim edit: when two of the listed procedure codes are billed on the same date, test the pair against the NCCI edits before relying on both being paid.

A56692: Billing and Coding: Scanning Computerized Ophthalmic Diagnostic Imaging (SCODI) (Billing and Coding, effective 2026-08-06)

Covered ICD-10-CM codes
720
1 group
Non-covered ICD-10-CM codes
0
Procedure codes listed
3
Full article
cms.gov record
First 24 covered ICD-10-CM codes in A56692
ICD-10-CMDescription (FY2027)
A18.53Tuberculous chorioretinitis
B39.4Histoplasmosis capsulati, unspecified
B39.5Histoplasmosis duboisii
B39.9Histoplasmosis, unspecified
C69.31Malignant neoplasm of right choroid
C69.32Malignant neoplasm of left choroid
D18.09Hemangioma of other sites
D31.31Benign neoplasm of right choroid
D31.32Benign neoplasm of left choroid
E08.3211Diabetes mellitus due to underlying condition with mild nonproliferative diabetic retinopathy with macular edema, right eye
E08.3212Diabetes mellitus due to underlying condition with mild nonproliferative diabetic retinopathy with macular edema, left eye
E08.3213Diabetes mellitus due to underlying condition with mild nonproliferative diabetic retinopathy with macular edema, bilateral
E08.3291Diabetes mellitus due to underlying condition with mild nonproliferative diabetic retinopathy without macular edema, right eye
E08.3292Diabetes mellitus due to underlying condition with mild nonproliferative diabetic retinopathy without macular edema, left eye
E08.3293Diabetes mellitus due to underlying condition with mild nonproliferative diabetic retinopathy without macular edema, bilateral
E08.3311Diabetes mellitus due to underlying condition with moderate nonproliferative diabetic retinopathy with macular edema, right eye
E08.3312Diabetes mellitus due to underlying condition with moderate nonproliferative diabetic retinopathy with macular edema, left eye
E08.3313Diabetes mellitus due to underlying condition with moderate nonproliferative diabetic retinopathy with macular edema, bilateral
E08.3391Diabetes mellitus due to underlying condition with moderate nonproliferative diabetic retinopathy without macular edema, right eye
E08.3392Diabetes mellitus due to underlying condition with moderate nonproliferative diabetic retinopathy without macular edema, left eye
E08.3393Diabetes mellitus due to underlying condition with moderate nonproliferative diabetic retinopathy without macular edema, bilateral
E08.3411Diabetes mellitus due to underlying condition with severe nonproliferative diabetic retinopathy with macular edema, right eye
E08.3412Diabetes mellitus due to underlying condition with severe nonproliferative diabetic retinopathy with macular edema, left eye
E08.3413Diabetes mellitus due to underlying condition with severe nonproliferative diabetic retinopathy with macular edema, bilateral

Procedure codes: 92133, 92134, 92137.

Coverage indications, limitations and medical necessity

Abstract:

Glaucoma is a leading cause of blindness, and a disease for which treatment methods clearly are available and in common use. Glaucoma also is diagnostically challenging. Almost 50% of glaucoma cases remain undetected. Elevated intraocular pressure is a clear risk factor for glaucoma, but over 30% of those suffering from the disease have pressures in the normal range. Further, most patients having abnormally high pressures will never suffer glaucomatous damage to their vision. Scanning computerized ophthalmic diagnostic imaging (SCODI) allows for early detection of glaucomatous damage to the nerve fiber layer or optic nerve of the eye. It is the goal of these diagnostic imaging tests to discriminate among patients with normal intraocular pressures (IOP) who have glaucoma, patients with elevated IOP who have glaucoma, and patients with elevated IOP who do not have glaucoma. These tests can also provide precise methods of observation of the optic nerve head and can more accurately reveal subtle glaucomatous changes over the course of follow-up exams than visual field and/or disc photos. This can allow earlier and more efficient treatment of the disease process.

Retinal disorders are the most common causes of severe and permanent vision loss. Scanning computerized ophthalmic diagnostic imaging (SCODI) is a valuable tool for the evaluation and treatment of patients with retinal disease, especially macular abnormalities. SCODI is able to detail the microscopic anatomy of the retina and the vitreo-retinal interface. SCODI is useful to measure the effectiveness of therapy, and in determining the need for ongoing therapy, or the safety of cessation of that therapy.

Many forms of scanning computerized ophthalmic diagnostic imaging tests currently exist (e.g., confocal laser scanning ophthalmoscopy [topography], scanning laser polarimetry, optical coherence tomography [OCT], and retinal thickness analysis). Although these techniques are different, their objective is the same. Medicare will consider scanning computerized ophthalmic diagnostic imaging (SCODI) medically reasonable and necessary in evaluating retinal disorders and glaucoma as documented in this local coverage determination (LCD).

Indications and Limitations:

Glaucoma

Glaucoma commonly causes a spectrum of related eye and vision changes, including erosion of the optic nerve and the associated retinal nerve fibers, and also loss of peripheral vision. A diagnosis of glaucoma seldom is made on the basis of a single clinical observation, but instead relies upon analysis of an assemblage of clinical data, including: optic nerve, retinal nerve fiber, and anterior chamber structure, as well as looking for hemorrhages of the optic nerve, pigment in the anterior chamber, and, especially visual field loss. Each of these methods has its own strengths and limitations, and none is immune to error thus the dependence upon multiple observations. Careful reliance upon all available clinical data can allow early treatment and can prevent unnecessary end-stage therapies.

SCODI allows earlier detection of those patients with normal tension glaucoma and more sophisticated analysis for ongoing management. This technology can distinguish patients with glaucomatous damage irrespective of the status of intraocular pressure. It may separate patients with elevated intraocular pressure and early glaucoma damage from those without glaucoma. This allows early treatment of the disease, preventing unnecessary medical or surgical therapy.

The following codes would generally not be necessary with SCODI. When needed the same day, documentation must justify the procedures.

• 92250 (descriptor licensed by AMA)

• 92225 - Ophthalmoscopy, extended with retinal drawing (e.g., for retinal detachment, melanoma) with interpretation and report; initial

• 92226 - Subsequent ophthalmoscopy

• 76512 - (descriptor licensed by AMA)

Scanning computerized ophthalmic diagnostic imaging is not considered medically reasonable and necessary when performed to provide additional confirmatory information regarding a diagnosis or treatment which has already been determined. However, the physician is not precluded from performing one of the listed procedures on the same eye of the patient on the same day, when each is necessary to evaluate and treat the patient. The reason for SCODI in addition to one of the above procedures must be clearly stated in the record.

Glaucoma may be diagnosed as mild, moderate, or severe and SCODI can be utilized as documented below.

Glaucoma Suspect or Mild Damage

SCODI can be used to follow pre-glaucoma patients or those with “mild” damage and who would demonstrate any or all of the following:

Visual Field

• no detectable VF defect;

• "mild" generalized reduction in retinal sensitivity;

• "mild" constriction of isopters;

• nasal step peripheral to 20 degrees; and/or

• small relative defects of the Bjerrum area, peripheral to 9 degrees.

Optic Nerve

• symmetric or vertically elongated cup enlargement; neural rim intact, rim: disc ratio> 0.2; cup:disc ratio 0.2; cup:disc ratio

Moderate Glaucomatous Damage

In patients with moderate glaucomatous damage, alternating the use of SCODI and visual field tests within correct time intervals will be considered appropriate, and may increase the sensitivity of detecting glaucomatous damage. Performance of SCODI and visual field tests on the same day, or separated by a short period of time (within three [3] months) is usually not considered medically necessary. However, there may be instances in which each test is needed to determine the patient's status and thus, treatment. The contractor expects use of both tests on the same day or during short intervals will be the exception rather than the rule.

Examples in which each test could be medically necessary include situations in which the clinical examination suggests progression of the glaucoma, yet the visual fields do not show new deficits. SCODI could be used to determine whether there is a change in the nerve fiber loss. Similarly, if the clinical examination showed progression and SCODI was unchanged, the visual field testing might be medically necessary to ascertain whether there is a functional loss of vision. If each test is performed on the same day or within short intervals, the medically necessary rationale must be present in the medical record.

Patients with moderate glaucomatous damage would demonstrate any or all of the following:

Visual Field

• "moderate" generalized reduction in retinal sensitivity;

• "moderate" constriction of isopters absolute defects to within 9 degrees of fixation; and/or

• temporal wedge.

Optic Nerve

• enlarged optic nerve cup with neural rim remaining but sloped or pale;

• focal notches with rim:disc ratio> 0.1 but 0.8 but

Advanced Glaucomatous Damage

Scanning computerized ophthalmic diagnostic imaging is not considered medically reasonable and necessary for patients with “advanced” glaucomatous damage. Instead, visual field testing should be performed. (Late in the course of glaucoma, when the nerve fiber layer has been extensively damaged, visual fields are more likely to detect small changes than scanning computerized ophthalmic diagnostic imaging). Patients with “advanced” glaucomatous damage would demonstrate any or all of the following:

Visual Field

• "severe" generalized reduction in retinal sensitivity;

• "severe" constriction of isopters (i.e., 14e

• absolute defects to within 3 degrees of fixation;

• loss of central acuity; and/or

• temporal island remains.

Optic Nerve

• diffuse enlargement of optic nerve cup; rim:disc ratio 0.9; and/or

• wipe out of all or a portion of the neuroretinal rim.

Retinal Disorders

Retinal disorders are the most common causes of severe and permanent vision loss. Scanning computerized ophthalmic diagnostic imaging (SCODI) is a valuable tool for the evaluation and treatment of patients with retinal disease, especially macular abnormalities. SCODI is able to detail the microscopic anatomy of the retina and the vitreo-retinal interface. SCODI is useful to measure the effectiveness of therapy, and in determining the need for ongoing therapy, or the safety of cessation of that therapy. SCODI is useful in evaluating retinal disorders and glaucoma.

Retinal thickness analysis is a non-invasive and non-contact imaging technique that takes direct cross-sectional images of the retina. These high resolution images capture ocular structures and provide data to create thickness maps of the retina. Retinal thickness is directly correlated to ocular disease, including retinal disorders and glaucoma.

In contrast, Scanning Laser Polarimetry is not an appropriate diagnostic technique for the management of retinal disorders.

Long Term Use of Chlorquine (CQ) and or Hydroxychloroquine (HCQ)

Clinical evidence has shown that long-term use of chloroquine (CQ) and/or hydroxychloroquine (HCQ) can lead to irreversible retinal toxicity. Therefore, these two medications are deemed high risk, and scanning optical coherence tomography may be indicated to provide a baseline prior to starting the medication and as an annual follow-up. Clinical evidence shows that the resolution of time domain OCT instruments is not sufficient to detect early toxic retinal changes. Because of that, spectral domain-optical coherence tomography (SD-OCT) is expected to be used to detect retinal changes that are due to the use of CQ or HCQ.

Other Comments:

For claims submitted to the Part A MAC: this coverage determination also applies within states outside the primary geographic jurisdiction with facilities that have nominated CGS Administrators, LL to process their claims.

Bill type codes only apply to providers who bill these services to the Part A MAC. Bill type codes do not apply to physicians, other professionals and suppliers who bill these services to the carrier or Part B MAC.

Limitation of liability and refund requirements apply when denials are likely, whether based on medical necessity or other coverage reasons. The provider/supplier must notify the beneficiary in writing, prior to rendering the service, if the provider/supplier is aware that the test, item or procedure may not be covered by Medicare. The limitation of liability and refund requirements do not apply when the test, item or procedure is statutorily excluded, has no Medicare benefit category or is rendered for screening purposes.

For dates of service on or after April 1, 2010, bill type 77X should be used to report FQHC services.

Summary of evidence (opening)

N/A

the full summary and analysis of evidence are in the CMS record.

Dates, lineage and related policies

Original determination effective
2015-10-01
Current revision effective
2026-08-06
Last reviewed by the contractor
2026-07-21
MCD version
26
Derived from
L31897

The contractor lists 4 National Coverage Determinations as related: NCD 80.6 Intraocular Photography, NCD 80.9 Computer Enhanced Perimetry, NCD 140.5 Laser Procedures, NCD 220.1 Computed Tomography. Where an NCD speaks, it controls; the LCD can only address what the NCD leaves open.

Using this policy on a claim

Match the documented indication to the covered indications above before the service is scheduled, carry a diagnosis from the article's covered list on the claim line (the diagnosis coverage checker tests one code pair against every article that applies in a state), and keep the elements the documentation section asks for in the record, because the contractor can request it later through medical review. A denial under this policy arrives as CARC 50 with remark N115; the LCD lookup guide walks through the appeal path and the Advance Beneficiary Notice rules, and the CGS Administrators, LLC hub lists every other active policy from the same contractor.

The same policy title at other contractors

Contractors often adopt each other's policies and then revise them separately, so the criteria and the diagnosis lists drift apart. The topic comparison lines up every version.

For teams evaluating QuickIntell software

Where QuickIntell fits with this policy

If your team repeatedly reviews local coverage policies, explore QuickAuth for requirement checks, documentation and status tracking with staff oversight. Confirm the applicable policy, supported workflow and review responsibilities. Use QuickRCM to evaluate the separate claim and denial workflow.

Optional software evaluation, not payer support or help with an individual claim. For coverage or payment decisions, use the official sources on this page. Do not include patient information in a demo booking or inquiry.

Frequently asked questions

What does LCD L34061 cover?

Glaucoma is a leading cause of blindness, and a disease for which treatment methods clearly are available and in common use. Glaucoma also is diagnostically challenging. Almost 50% of glaucoma cases remain undetected. Elevated intraocular pressure is a clear risk factor for glaucoma, but over 30% of those suffering from the disease have pressures in the normal range. Further, most patients having abnormally high… The full 1,587-word policy text is reproduced below from the Medicare Coverage Database export of November 12, 2026.

Which states does LCD L34061 apply to?

CGS Administrators, LLC applies it to Medicare claims in 2 states: KY, OH. It binds only that contractor; 5 other contractor versions of this title govern other jurisdictions, and elsewhere the same service is judged under the local contractor's own policy or, where none exists, claim by claim.

Which diagnosis codes support medical necessity under LCD L34061?

The companion billing and coding article A56692 lists 720 ICD-10-CM codes in 1 group that support medical necessity; the first 24 appear on this page, where the complete list opens by group with the contractor's group instructions.

How do I appeal a denial under LCD L34061?

A denial under LCD L34061 carries claim adjustment reason code 50 with remark code N115. Compare the documented indication with the policy's covered indications and article A56692's 720 covered diagnosis codes, then file a redetermination with CGS Administrators, LLC within 120 days, record attached. If the service falls outside the policy, bill the patient only with a valid Advance Beneficiary Notice signed before the service.

Sources

Every figure on this page is taken from the CMS publications below, as released by the Centers for Medicare & Medicaid Services. Projection built 2026-11-16. Verify against the primary file before billing or contracting decisions. The reference methodology explains how each figure is computed from these files.

Disclaimer

The policy text and code lists are reproduced from the CMS Medicare Coverage Database export as an operational reference. Verify against the current LCD and article on cms.gov before billing; coverage depends on the full record and the contractor. Not legal, clinical or billing advice.

Found a figure that does not match the CMS file? Report a data correction with the CMS file and the value you expected; the request reaches the editorial team through the contact form.