Skip to main content

LCD L34087: Surveillance of Implantable or Wearable Cardioverter Defibrillators (ICDs): Office, Hospital, Web, or Non-Web Based

LCD L34087, Surveillance of Implantable or Wearable Cardioverter Defibrillators (ICDs): Office, Hospital, Web, or Non-Web Based, is the Local Coverage Determination that CGS Administrators, LLC applies to claims from 2 states (KY, OH), effective 2026-09-03 and first in force 2015-10-01. The policy text runs 797 words, and its billing and coding article A57038 lists 33 ICD-10-CM codes that support medical necessity for 8 procedure codes. No other contractor publishes a policy with this title.

QuickIntell editorial content · Legacy registry date · Review not verified

Data effective
Data currency: Medicare Coverage Database LCD export release of September 24, 2026 (effective September 20, 2026). Next CMS release: weekly (Thursdays) for the MCD.
Contractor
CGS Administrators, LLC
States and territories
2
KY OH
Revision effective
2026-09-03
Original effective
2015-10-01
Policy text
797 words
Covered ICD-10 codes (articles)
33

Where this LCD applies

Each contract number is a jurisdiction on the remittance; the policy binds claims processed under these contracts and no others.

Contracts that apply LCD L34087
ContractContractorTypeStates
15102CGS Administrators, LLCMAC - Part BKY
15202CGS Administrators, LLCMAC - Part BOH
15101CGS Administrators, LLCMAC - Part AKY
15201CGS Administrators, LLCMAC - Part AOH

Billing and coding: diagnoses and procedure codes

Since 2019 the codes live in the companion article rather than the LCD. Billing and Coding A57038 (Billing and Coding: Surveillance of Implantable or Wearable Cardioverter Defibrillators (ICDs): Office, Hospital, Web, or Non-Web Based) carries the diagnosis and procedure lists the contractor loads as the claims edit. CPT codes are shown as bare numbers because the descriptors are licensed by the AMA; HCPCS Level II descriptors are public and shown.

A57038: Billing and Coding: Surveillance of Implantable or Wearable Cardioverter Defibrillators (ICDs): Office, Hospital, Web, or Non-Web Based (Billing and Coding, effective 2026-09-03)

Covered ICD-10-CM codes
33
1 group
Non-covered ICD-10-CM codes
0
Procedure codes listed
8
Full article
cms.gov record
First 24 covered ICD-10-CM codes in A57038
ICD-10-CMDescription (FY2027)
I46.2—
I46.8—
I47.0—
I47.21—
I47.29—
I47.9—
I49.01—
I49.02—
R00.0—
R00.2—
R42Dizziness and giddiness
R55Syncope and collapse
T82.110A—
T82.111A—
T82.118A—
T82.120A—
T82.121A—
T82.128A—
T82.190A—
T82.191A—
T82.198A—
T82.817A—
T82.827A—
T82.837A—

Procedure codes: 93282, 93283, 93284, 93287, 93289, 93292, 93295, 93296.

Coverage indications, limitations and medical necessity

Abstract:

Implanted cardioverter-defibrillators require periodic evaluation of function and reprogramming based upon the patient's medical condition. Interrogation may be provided during a face-to-face encounter or remotely. The interrogation and evaluation may be provided as routine follow-up in an asymptomatic patient without device discharge, or for symptoms, with device discharge. Reprogramming should be reflected by a need for change in the patient's medical condition.

Remote interrogation is a 90-day service, inclusive of all transmissions during that period which are then billed as a single service. A provider may not bill a remote service and a face-to-face service on the same day.

Medicare will cover surveillance of ICDs as a face-to-face or remote service to monitor behavior of the device, to investigate symptoms such as post-event shock, and syncope, ICD malfunction or device failure. Surveillance of ICDs is also indicated to program device evaluation and adjustment and for patients prior to surgery or other procedures to modify or disable the device during the procedure. Remote interrogation is a single 90-day service, while in-person interrogation can be reported for each day it is performed.

Peri-procedural device evaluation and programming before and/or after a procedure or test may be reported separately.

Indications and Limitations:

Surveillance of an ICD is indicated to monitor the behavior of the device and to assess the patient with intervening symptoms. The frequency and need for both face-to-face and remote interrogation should be coordinated so that there is no unnecessary duplication of the interrogation services.

The symptoms requiring unscheduled investigation by both remote and face-to-face modalities should be discrete symptoms such as post-shock events, syncope/near-syncope and palpitations. Remote and face-to-face interrogations may be performed for suspected malfunction or device failure.

In-person evaluation/interrogation services (93287, 93289, and 93292) may be reported each time they are provided (reimbursement is dependent upon documentation of medical necessity).

Remote interrogation services 93295 and 93296 are 90-day services, and may only be reported once during that period regardless of the number of interrogations performed. The 90-day period begins with the initiation of remote monitoring or the 91st day of the implantable defibrillator.

In-person interrogation occurring during the same 90-day period as remote interrogation is included in the remote interrogation service. If there is no interrogation service provided within a 90-day period then the service should not be billed for that period. Programming services may be reported separately.

In-person interrogation performed on the same day as the programming of the device is included in the programming service.

Interrogation and reprogramming of defibrillators prior to and after a surgical procedure or test (93287) is covered as a separate procedure when it is necessary to modify how the device would function during the procedure/test (e.g., to avoid interference by an electrical cautery during the procedure, to disable during cardiac surgery, etc).

When performing program device evaluation with iterative adjustment of the device to test function and select optimal programmed parameters, the final parameters may or may not change from previous parameters. Documentation of each parameter tested and the result should be maintained in the record.

For physician billing, each interrogation, with/without reprogramming must be provided under personal supervision of the physician in a hospital or other facility setting and at least direct supervision in the office or private clinic setting. The physician must personally review and analyze the data, and generate a report.

For hospital billing, each interrogation, with/without reprogramming must be provided under direct supervision of a qualified physician in the hospital. A qualified physician must personally review and analyze the data, and generate a report.

When the technical portion of interrogation services are provided by a service center (IDTF, hospital based laboratory, etc), or physician other than the one analyzing and interpreting the results (93296), the physician performing the review, analysis and report must generate his/her own interpretation and report (with signature) and not just countersign the technical review and distribution of results.

These evaluation/interrogation services should not be billed when implanting or replacing an ICD.

The service must be prescribed by a physician or a qualified non-physician practitioner.

An evaluation and management (E&M) service provided on the same day as in-person interrogation/programming must be a significant and separately identifiable face-to-face service. No part of the ICD surveillance (face-to-face or Internet based) may be reported as an E&M service. A brief history to ascertain whether the device has discharged or patient has had symptoms relevant to the need for the device (and therefore function) is considered part of the surveillance service. EKG rhythm strips (93040-93042) are included in these evaluation/interrogation services and should not be billed separately.

Coverage is limited to system(s) approved by the FDA for patients with a specific implanted ICD model.

Only physicians who have expertise and/or training in reprogramming of ICDs may bill the interrogation with or without reprogramming services.

Summary of evidence (opening)

N/A

the full summary and analysis of evidence are in the CMS record.

Dates, lineage and related policies

Original determination effective
2015-10-01
Current revision effective
2026-09-03
Last reviewed by the contractor
2026-08-14
MCD version
21
Derived from
L31904

Using this policy on a claim

Match the documented indication to the covered indications above before the service is scheduled, carry a diagnosis from the article's covered list on the claim line, and keep the elements the documentation section asks for in the record, because the contractor can request it later through medical review. A denial under this policy arrives as CARC 50 with remark N115; the LCD lookup guide walks through the appeal path and the Advance Beneficiary Notice rules, and the CGS Administrators, LLC hub lists every other active policy from the same contractor.

Frequently asked questions

What does LCD L34087 cover?

Implanted cardioverter-defibrillators require periodic evaluation of function and reprogramming based upon the patient's medical condition. Interrogation may be provided during a face-to-face encounter or remotely. The interrogation and evaluation may be provided as routine follow-up in an asymptomatic patient without device discharge, or for symptoms, with device discharge. Reprogramming should be reflected by a… The full indications and limitations are reproduced on this page from the CMS Medicare Coverage Database export of September 24, 2026.

Which states does LCD L34087 apply to?

CGS Administrators, LLC applies it to Medicare claims in KY, OH. A Local Coverage Determination binds only the contractor that wrote it; the same service in another jurisdiction is judged under that contractor's own policy or, where none exists, claim by claim.

Which diagnosis codes support medical necessity under LCD L34087?

The companion billing and coding article A57038 lists 33 ICD-10-CM codes in 1 group that support medical necessity; the first 24 appear on this page and the complete list is in the article on cms.gov.

How do I appeal a denial under LCD L34087?

The remittance carries claim adjustment reason code 50 with remark code N115, naming the LCD. Compare the documented indication with the policy's covered indications and the article's diagnosis list, then file a redetermination within 120 days with the record attached; if the service genuinely falls outside the policy, the patient can be billed only when a valid Advance Beneficiary Notice was obtained before the service.

Sources

Every figure on this page is taken from the CMS publications below, as released by the Centers for Medicare & Medicaid Services. Projection built 2026-10-02. Verify against the primary file before billing or contracting decisions.

Disclaimer

The policy text and code lists are reproduced from the CMS Medicare Coverage Database export as an operational reference. Verify against the current LCD and article on cms.gov before billing; coverage depends on the full record and the contractor. Not legal, clinical or billing advice.