Skip to main content

LCD L33796: Osteogenesis Stimulators

LCD L33796, Osteogenesis Stimulators, is the Local Coverage Determination that Noridian Healthcare Solutions, LLC and CGS Administrators, LLC apply to claims from 56 states (AK, AL, AR, AS, AZ, CA, CNMI, CO and others), effective 2024-01-01 and first in force 2015-10-01. The policy text runs 1,237 words. No other contractor publishes a policy with this title.

QuickIntell editorial content · Legacy registry date · Review not verified

Data effective
Data currency: Medicare Coverage Database LCD export release of September 24, 2026 (effective September 20, 2026). Next CMS release: weekly (Thursdays) for the MCD.
Contractor
Noridian Healthcare Solutions, LLC; CGS Administrators, LLC
States and territories
56
AK AL AR AS AZ CA CNMI CO CT DC DE FL GA GU HI IA ID IL IN KS KY LA MA MD ME MI MN MO MS MT NC ND NE NH NJ NM NV NY OH OK OR PA PR RI SC SD TN TX UT VA VI VT WA WI WV WY
Revision effective
2024-01-01
Original effective
2015-10-01
Policy text
1,237 words
Covered ICD-10 codes (articles)
0

Where this LCD applies

Each contract number is a jurisdiction on the remittance; the policy binds claims processed under these contracts and no others.

Contracts that apply LCD L33796
ContractContractorTypeStates
19003Noridian Healthcare Solutions, LLCDME MACAK AS AZ CA CNMI GU HI IA ID KS MO MT ND NE NV OR SD UT WA WY
18003CGS Administrators, LLCDME MACAL AR CO FL GA LA MS NC NM OK PR SC TN TX VA VI WV
17013CGS Administrators, LLCDME MACIL IN KY MI MN OH WI
16013Noridian Healthcare Solutions, LLCDME MACCT DC DE MA MD ME NH NJ NY PA RI VT

Procedure codes named in the LCD

A4559 (Coupling Gel Or Paste, For Use With Ultrasound Device, Per Oz), E0747 (Osteogenesis Stimulator, Electrical, Non-Invasive, Other Than Spinal Applications), E0748 (Osteogenesis Stimulator, Electrical, Non-Invasive, Spinal Applications), E0760 (Osteogenesis Stimulator, Low Intensity Ultrasound, Non-Invasive).

Coverage indications, limitations and medical necessity

For any item to be covered by Medicare, it must 1) be eligible for a defined Medicare benefit category, 2) be reasonable and necessary for the diagnosis or treatment of illness or injury or to improve the functioning of a malformed body member, and 3) meet all other applicable Medicare statutory and regulatory requirements.

The purpose of a Local Coverage Determination (LCD) is to provide information regarding “reasonable and necessary” criteria based on Social Security Act § 1862(a)(1)(A) provisions.

In addition to the “reasonable and necessary” criteria contained in this LCD there are other payment rules, which are discussed in the following documents, that must also be met prior to Medicare reimbursement:

• The LCD-related Standard Documentation Requirements Article, located at the bottom of this policy under the Related Local Coverage Documents section.

• The LCD-related Policy Article, located at the bottom of this policy under the Related Local Coverage Documents section.

• Refer to the Supplier Manual for additional information on documentation requirements.

• Refer to the DME MAC web sites for additional bulletin articles and other publications related to this LCD.

For the items addressed in this LCD, the “reasonable and necessary” criteria, based on Social Security Act § 1862(a)(1)(A) provisions, are defined by the following coverage indications, limitations and/or medical necessity.

A non-spinal electrical osteogenesis stimulator (E0747) is covered only if any of the following criteria are met:

• Nonunion of a long bone fracture (see Appendices section) defined as radiographic evidence that fracture healing has ceased for three or more months prior to starting treatment with the osteogenesis stimulator, or

• Failed fusion of a joint other than in the spine where a minimum of nine months has elapsed since the last surgery, or

• Congenital pseudarthrosis.

Nonunion of a long bone fracture must be documented by a minimum of two sets of radiographs obtained prior to starting treatment with the osteogenesis stimulator, separated by a minimum of 90 days, each including multiple views of the fracture site, and with a written interpretation by a treating practitioner stating that there has been no clinically significant evidence of fracture healing between the two sets of radiographs.

A non-spinal electrical osteogenesis stimulator will be denied as not medically necessary if none of the criteria above are met.

A spinal electrical osteogenesis stimulator (E0748) is covered only if any of the following criteria are met:

• Failed spinal fusion where a minimum of nine months has elapsed since the last surgery, or

• Following a multilevel spinal fusion surgery (see Appendices section), or

• Following spinal fusion surgery where there is a history of a previously failed spinal fusion at the same site.

A spinal electrical osteogenesis stimulator will be denied as not medically necessary if none of the criteria above are met.

An ultrasonic osteogenesis stimulator (E0760) is covered only if all of the following criteria are met:

• Nonunion of a fracture documented by a minimum of two sets of radiographs obtained prior to starting treatment with the osteogenesis stimulator, separated by a minimum of 90 days. Each radiograph set must include multiple views of the fracture site accompanied by a written interpretation by a treating practitioner stating that there has been no clinically significant evidence of fracture healing between the two sets of radiographs; and

• The fracture is not of the skull or vertebrae; and

• The fracture is not tumor related.

An ultrasonic osteogenesis stimulator will be denied as not medically necessary if any of the criteria above are not met.

Use of an ultrasonic osteogenesis stimulator for the treatment of a fresh fracture or delayed union will be denied as not medically necessary.

Ultrasound conductive coupling gel is covered and separately payable if an ultrasonic osteogenesis stimulator is covered.

An ultrasonic osteogenesis stimulator will be denied as not medically necessary if it is used with other noninvasive osteogenesis stimulators.

GENERAL

A Standard Written Order (SWO) must be communicated to the supplier before a claim is submitted. If the supplier bills for an item addressed in this policy without first receiving a completed SWO, the claim shall be denied as not reasonable and necessary.

For Durable Medical Equipment, Prosthetics, Orthotics and Supplies (DMEPOS) base items that require a Written Order Prior to Delivery (WOPD), the supplier must have received a signed SWO before the DMEPOS item is delivered to a beneficiary. If a supplier delivers a DMEPOS item without first receiving a WOPD, the claim shall be denied as not reasonable and necessary. Refer to the LCD-related Policy Article, located at the bottom of this policy under the Related Local Coverage Documents section.

For DMEPOS base items that require a WOPD, and also require separately billed associated options, accessories, and/or supplies, the supplier must have received a WOPD which lists the base item and which may list all the associated options, accessories, and/or supplies that are separately billed prior to the delivery of the items. In this scenario, if the supplier separately bills for associated options, accessories, and/or supplies without first receiving a completed and signed WOPD of the base item prior to delivery, the claim(s) shall be denied as not reasonable and necessary.

An item/service is correctly coded when it meets all the coding guidelines listed in CMS HCPCS guidelines, LCDs, LCD-related Policy Articles, or DME MAC articles. Claims that do not meet coding guidelines shall be denied as not reasonable and necessary/incorrectly coded.

Proof of delivery (POD) is a Supplier Standard and DMEPOS suppliers are required to maintain POD documentation in their files. Proof of delivery documentation must be made available to the Medicare contractor upon request. All services that do not have appropriate proof of delivery from the supplier shall be denied as not reasonable and necessary.

REFILL REQUIREMENTS

For DMEPOS items and supplies provided on a recurring basis, billing must be based on prospective, not retrospective use. For DMEPOS products that are supplied as refills to the original order, suppliers must contact the beneficiary, and document an affirmative response, prior to dispensing the refill and not automatically ship on a pre-determined basis, even if authorized by the beneficiary. This shall be done to ensure that the refilled item remains reasonable and necessary, existing supplies are expected to end, and to confirm any changes or modifications to the order. Contact with the beneficiary or designee regarding refills must take place no sooner than 30 calendar days prior to the expected end of the current supply. For delivery of refills, the supplier must deliver the DMEPOS product no sooner than 10 calendar days prior to the expected end of the current supply. This is regardless of which delivery method is utilized.

For all DMEPOS items that are provided on a recurring basis, suppliers are required to have contact with the beneficiary or caregiver/designee and document an affirmative response, prior to dispensing a new supply of items. Suppliers must not deliver refills without a refill request and an affirmative response from a beneficiary. Items delivered without a valid, documented refill request will be denied as not reasonable and necessary.

Suppliers must not dispense a quantity of supplies exceeding a beneficiary's expected utilization. Suppliers must stay attuned to changed or atypical utilization patterns on the part of their clients. Suppliers must verify with the treating practitioners that any changed or atypical utilization is warranted. Regardless of utilization, a supplier must not dispense more than a three (3)-month quantity at a time.

Summary of evidence (opening)

Per the 2022 Medicare Fee-for Service Supplemental Improper Payment Data, the overall CERT error rate for DMEPOS claims is 25.2%. Claims for items which have recently had Certificates of Medical Necessity (CMNs) or Durable Medical Equipment Information Forms (DIFs) eliminated represent an area of potential vulnerability that may increase the CERT error rate.

the full summary and analysis of evidence are in the CMS record.

Dates, lineage and related policies

Original determination effective
2015-10-01
Current revision effective
2024-01-01
MCD version
24
Derived from
L11501

The contractor lists one National Coverage Determination as related: NCD 150.2 Osteogenic Stimulators. Where an NCD speaks, it controls; the LCD can only address what the NCD leaves open.

Other related documents: A52513 (Article), A55426 (Article), A59402 (Response to Comments).

Using this policy on a claim

Match the documented indication to the covered indications above before the service is scheduled, carry a diagnosis from the article's covered list on the claim line, and keep the elements the documentation section asks for in the record, because the contractor can request it later through medical review. A denial under this policy arrives as CARC 50 with remark N115; the LCD lookup guide walks through the appeal path and the Advance Beneficiary Notice rules, and the Noridian Healthcare Solutions, LLC hub and CGS Administrators, LLC hub list every other active policy from the same contractor.

Frequently asked questions

What does LCD L33796 cover?

A non-spinal electrical osteogenesis stimulator (E0747) is covered only if any of the following criteria are met: The full indications and limitations are reproduced on this page from the CMS Medicare Coverage Database export of September 24, 2026.

Which states does LCD L33796 apply to?

Noridian Healthcare Solutions, LLC and CGS Administrators, LLC apply it to Medicare claims in AK, AL, AR, AS, AZ, CA, CNMI, CO, CT, DC, DE, FL, GA, GU, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, PR, RI, SC, SD, TN, TX, UT, VA, VI, VT, WA, WI, WV, WY. A Local Coverage Determination binds only the contractor that wrote it; the same service in another jurisdiction is judged under that contractor's own policy or, where none exists, claim by claim.

Which diagnosis codes support medical necessity under LCD L33796?

The current export links no billing and coding article with a diagnosis list to this LCD, so coverage is decided on the indications in the policy text and the documentation in the record rather than by an automated diagnosis edit.

How do I appeal a denial under LCD L33796?

The remittance carries claim adjustment reason code 50 with remark code N115, naming the LCD. Compare the documented indication with the policy's covered indications and the article's diagnosis list, then file a redetermination within 120 days with the record attached; if the service genuinely falls outside the policy, the patient can be billed only when a valid Advance Beneficiary Notice was obtained before the service.

Sources

Every figure on this page is taken from the CMS publications below, as released by the Centers for Medicare & Medicaid Services. Projection built 2026-10-02. Verify against the primary file before billing or contracting decisions.

Disclaimer

The policy text and code lists are reproduced from the CMS Medicare Coverage Database export as an operational reference. Verify against the current LCD and article on cms.gov before billing; coverage depends on the full record and the contractor. Not legal, clinical or billing advice.