Where this LCD applies
Each contract number is a jurisdiction on the remittance; the policy binds claims processed under these contracts and no others.
| Contract | Contractor | Type | States |
|---|---|---|---|
| 09101 | First Coast Service Options, Inc. | A and B MAC | FL |
| 09201 | First Coast Service Options, Inc. | A and B MAC | PR VI |
| 09102 | First Coast Service Options, Inc. | A and B MAC | FL |
| 09202 | First Coast Service Options, Inc. | A and B MAC | PR |
| 09302 | First Coast Service Options, Inc. | A and B MAC | VI |
Billing and coding article A56704: diagnoses and procedure codes
Since 2019 the codes live in the companion article rather than the LCD. Billing and Coding A56704 (Billing and Coding: Wireless Capsule Endoscopy) carries the diagnosis and procedure lists the contractor loads as the claims edit. CPT codes are shown as bare numbers because the descriptors are licensed by the AMA; HCPCS Level II descriptors are public and shown. Each article below opens its complete covered and non-covered ICD-10-CM lists, by group and with the contractor's group instructions, and the LCD code lookup answers whether one diagnosis is covered for one procedure code in a given state.
Coverage is only half of the claim edit: when two of the listed procedure codes are billed on the same date, test the pair against the NCCI edits before relying on both being paid.
A56704: Billing and Coding: Wireless Capsule Endoscopy (Billing and Coding, effective 2022-03-10)
- Covered ICD-10-CM codes
- 21
- 2 groups
- Non-covered ICD-10-CM codes
- 0
- Procedure codes listed
- 2
- Full article
- cms.gov record
| ICD-10-CM | Description (FY2027) |
|---|---|
| D50.0 | Iron deficiency anemia secondary to blood loss (chronic) |
| D50.9 | Iron deficiency anemia, unspecified |
| I85.10 | Secondary esophageal varices without bleeding |
| I85.11 | Secondary esophageal varices with bleeding |
| K50.00 | Crohn's disease of small intestine without complications |
| K50.011 | Crohn's disease of small intestine with rectal bleeding |
| K50.018 | Crohn's disease of small intestine with other complication |
| K50.019 | Crohn's disease of small intestine with unspecified complications |
| K50.80 | Crohn's disease of both small and large intestine without complications |
| K50.811 | Crohn's disease of both small and large intestine with rectal bleeding |
| K50.818 | Crohn's disease of both small and large intestine with other complication |
| K50.819 | Crohn's disease of both small and large intestine with unspecified complications |
| K50.90 | Crohn's disease, unspecified, without complications |
| K50.911 | Crohn's disease, unspecified, with rectal bleeding |
| K50.918 | Crohn's disease, unspecified, with other complication |
| K50.919 | Crohn's disease, unspecified, with unspecified complications |
| K55.21 | Angiodysplasia of colon with hemorrhage |
| K57.11 | Diverticulosis of small intestine without perforation or abscess with bleeding |
| K57.13 | Diverticulitis of small intestine without perforation or abscess with bleeding |
| K76.6 | Portal hypertension |
| K92.2 | Gastrointestinal hemorrhage, unspecified |
Procedure codes: 91110, 91111.
Coverage indications, limitations and medical necessity
Wireless capsule endoscopy (WCE) requires that the patient ingest a small capsule containing a disposable light source, miniature color video camera, battery, antenna and a data transmitter. The self-contained capsule is made of specially sealed biocompatible material that is resistant to the digestive fluids throughout the gastrointestinal (GI) tract. Following ingestion of the capsule, natural contraction and relaxation of the GI tract propels the capsule forward. The camera contained in the capsule records images as it travels through the digestive system. During the entire procedure, the patient wears a data recorder around the waist, which captures and stores images transmitted by the capsule’s camera. After completion of the procedure, the patient data recorder is connected to a computer workstation where the images are downloaded, reviewed, and interpreted by the physician. The procedure lasts approximately five minutes for observing the esophageal mucosa and approximately 8 hours when observing intestinal mucosa. The capsule is designed to be disposable and is excreted naturally from the body.
Covered Indications
Wireless capsule endoscopy of the small bowel is considered medically reasonable and necessary when the following conditions have been met:
• documented continuous blood loss and anemia secondary to obscure bleeding of the small bowel;
• the site of bleeding could not be previously identified by colonoscopy, or endoscopy, or;
• radiographic exams of the small bowel have failed to reveal a source, or;
• intraoperative enteroscopy is being considered, or;
• initial diagnosis of suspected Crohn’s Disease when there is no evidence provided by conventional diagnostic tests such as small bowel follow-through (SBFT), and upper and lower endoscopy.
Wireless capsule endoscopy of the esophagus is considered medically reasonable and necessary for the following condition, if the criteria have been met:
• Patient diagnosed with portal hypertension who requires immediate evaluation of esophageal varices
• AND the esophageal capsule endoscopy is performed in lieu of conventional endoscopy because the provider who would perform the endoscopy has determined that the patient’s current medical condition prohibits a conventional endoscopy.
• AND the medical record clearly reflects why the patient was not a candidate for conventional endoscopy and how the capsule endoscopy would contribute to the patient’s care.
Limitations
• Wireless capsule endoscopy of the esophagus will be considered medically necessary only as specified under “Covered Indications.” Performance of wireless capsule endoscopy for any other reason will be considered not medically necessary.
• Wireless capsule endoscopy is not reimbursable for colorectal cancer screening.
• This test is covered only for services using Food and Drug Administration (FDA) approved devices.
• Wireless capsule endoscopy is not indicated for the confirmation of lesions of pathology normally within the reach of upper and lower endoscopes (proximal to the ligament of Treitz, or distal to the ileum).
• The use of wireless capsule endoscopy should not be used in patients with a cardiac pacemaker, or other implanted electromagnetic device.
• This test is not indicated for patients in whom a radiological exam of the small bowel has confirmed an intestinal blockage, a significantly narrow small bowel, or an abnormal connection between the bowel and another organ.
• An x-ray exam of the small bowel should be done if there is concern that it may be too narrow for the camera.
Wireless capsule endoscopy of the small bowel is payable only once per episode of illness for patients who have previously undergone an upper GI endoscopy, and lower GI colonoscopy, but have failed to reveal a source of bleeding. An episode of illness is defined as the time frame from the onset of signs and symptoms until the GI bleeding is resolved.
As published in the CMS IOM Publication 100-08, Medicare Program Integrity Manual , Chapter 13, Section 13.5.4, an item or service may be covered by a contractor LCD if it is reasonable and necessary under the Social Security Act Section 1862 (a)(1)(A). Contractors shall determine and describe the circumstances under which the item or service is considered reasonable and necessary.
Provider Qualifications
Wireless Capsule Endoscopy is covered when performed only by providers of gastroenterology and radiology services or other providers who have specialized training and expertise in performing wireless capsule endoscopy. Training and expertise must have been acquired within the framework of an accredited residency and/or fellowship program in the applicable specialty/subspecialty. If this skill has been acquired as continuing medical education, the courses must be comprehensive, offered or sponsored or endorsed by an academic institution in the United States and/or by the applicable specialty/subspecialty society in the United States, and designated by the American Medical Association (AMA) as Category 1 Credit.
Summary of evidence (opening)
N/A
the full summary and analysis of evidence are in the CMS record.
Dates, lineage and related policies
- Original determination effective
- 2015-10-01
- Current revision effective
- 2019-07-11
- Last reviewed by the contractor
- 2018-06-26
- MCD version
- 15
- Derived from
- L29008
The contractor lists one National Coverage Determination as related: NCD 100.2 Endoscopy. Where an NCD speaks, it controls; the LCD can only address what the NCD leaves open.
Using this policy on a claim
Match the documented indication to the covered indications above before the service is scheduled, carry a diagnosis from the article's covered list on the claim line (the diagnosis coverage checker tests one code pair against every article that applies in a state), and keep the elements the documentation section asks for in the record, because the contractor can request it later through medical review. A denial under this policy arrives as CARC 50 with remark N115; the LCD lookup guide walks through the appeal path and the Advance Beneficiary Notice rules, and the First Coast Service Options, Inc. hub lists every other active policy from the same contractor.
The same policy title at other contractors
Contractors often adopt each other's policies and then revise them separately, so the criteria and the diagnosis lists drift apart. The topic comparison lines up every version.
For teams evaluating QuickIntell software
Where QuickIntell fits with this policy
If your team repeatedly reviews local coverage policies, explore QuickAuth for requirement checks, documentation and status tracking with staff oversight. Confirm the applicable policy, supported workflow and review responsibilities. Use QuickRCM to evaluate the separate claim and denial workflow.
Optional software evaluation, not payer support or help with an individual claim. For coverage or payment decisions, use the official sources on this page. Do not include patient information in a demo booking or inquiry.
Frequently asked questions
What does LCD L33774 cover?
Wireless capsule endoscopy (WCE) requires that the patient ingest a small capsule containing a disposable light source, miniature color video camera, battery, antenna and a data transmitter. The self-contained capsule is made of specially sealed biocompatible material that is resistant to the digestive fluids throughout the gastrointestinal (GI) tract. Following ingestion of the capsule, natural contraction… The full 761-word policy text is reproduced below from the Medicare Coverage Database export of November 12, 2026.
Which states does LCD L33774 apply to?
First Coast Service Options, Inc. applies it to Medicare claims in 1 state plus 2 territories: FL, PR, VI. It binds only that contractor; 2 other contractor versions of this title govern other jurisdictions, and elsewhere the same service is judged under the local contractor's own policy or, where none exists, claim by claim.
Which diagnosis codes support medical necessity under LCD L33774?
The companion billing and coding article A56704 lists 21 ICD-10-CM codes in 2 groups that support medical necessity; the first 21 appear on this page, where the complete list opens by group with the contractor's group instructions.
How do I appeal a denial under LCD L33774?
A denial under LCD L33774 carries claim adjustment reason code 50 with remark code N115. Compare the documented indication with the policy's covered indications and article A56704's 21 covered diagnosis codes, then file a redetermination with First Coast Service Options, Inc. within 120 days, record attached. If the service falls outside the policy, bill the patient only with a valid Advance Beneficiary Notice signed before the service.
Sources
Every figure on this page is taken from the CMS publications below, as released by the Centers for Medicare & Medicaid Services. Projection built 2026-11-16. Verify against the primary file before billing or contracting decisions. The reference methodology explains how each figure is computed from these files.
- Medicare Coverage Database, current LCD exportVersion MCD release 2026-11-12 · effective 2026-11-08 · file lcd.csvSHA-256 2e0eda3351aa3d47…
- Medicare Coverage Database, current Billing and Coding Articles exportVersion MCD release 2026-11-12 · effective 2026-11-08 · file article.csvSHA-256 b475751458564786…
- ICD-10-CM FY2027 code descriptionsVersion FY2027 · effective 2026-10-01 · file icd10cm_codes_2027.txtSHA-256 3c0583a38ee0e848…
Disclaimer
The policy text and code lists are reproduced from the CMS Medicare Coverage Database export as an operational reference. Verify against the current LCD and article on cms.gov before billing; coverage depends on the full record and the contractor. Not legal, clinical or billing advice.
Found a figure that does not match the CMS file? Report a data correction with the CMS file and the value you expected; the request reaches the editorial team through the contact form.