Where this LCD applies
Each contract number is a jurisdiction on the remittance; the policy binds claims processed under these contracts and no others.
| Contract | Contractor | Type | States |
|---|---|---|---|
| 06101 | Wellpoint Federal | MAC - Part A | IL |
| 06201 | Wellpoint Federal | MAC - Part A | MN |
| 06301 | Wellpoint Federal | MAC - Part A | WI |
| 06102 | Wellpoint Federal | MAC - Part B | IL |
| 06202 | Wellpoint Federal | MAC - Part B | MN |
| 06302 | Wellpoint Federal | MAC - Part B | WI |
| 13101 | Wellpoint Federal | A and B and HHH MAC | CT |
| 13201 | Wellpoint Federal | A and B and HHH MAC | NY |
| 13102 | Wellpoint Federal | A and B and HHH MAC | CT |
| 13202 | Wellpoint Federal | A and B and HHH MAC | DN |
| 13282 | Wellpoint Federal | A and B and HHH MAC | UN |
| 13292 | Wellpoint Federal | A and B and HHH MAC | QN |
| 14411 | Wellpoint Federal | A and B and HHH MAC | RI |
| 14211 | Wellpoint Federal | A and B and HHH MAC | MA |
| 14311 | Wellpoint Federal | A and B and HHH MAC | NH |
| 14511 | Wellpoint Federal | A and B and HHH MAC | VT |
| 14111 | Wellpoint Federal | A and B and HHH MAC | ME |
| 14112 | Wellpoint Federal | A and B and HHH MAC | ME |
| 14212 | Wellpoint Federal | A and B and HHH MAC | MA |
| 14312 | Wellpoint Federal | A and B and HHH MAC | NH |
| 14512 | Wellpoint Federal | A and B and HHH MAC | VT |
| 14412 | Wellpoint Federal | A and B and HHH MAC | RI |
Billing and coding: diagnoses and procedure codes
Since 2019 the codes live in the companion article rather than the LCD. Billing and Coding A56549 (Billing and Coding: Ophthalmic Biometry for Intraocular Lens Power Calculation) carries the diagnosis and procedure lists the contractor loads as the claims edit. CPT codes are shown as bare numbers because the descriptors are licensed by the AMA; HCPCS Level II descriptors are public and shown.
A56549: Billing and Coding: Ophthalmic Biometry for Intraocular Lens Power Calculation (Billing and Coding, effective 2026-04-01)
- Covered ICD-10-CM codes
- 97
- 1 group
- Non-covered ICD-10-CM codes
- 0
- Procedure codes listed
- 2
- Full article
- cms.gov record
| ICD-10-CM | Description (FY2027) |
|---|---|
| E10.36 | — |
| E11.36 | — |
| E13.36 | — |
| H25.011 | — |
| H25.012 | — |
| H25.013 | — |
| H25.031 | — |
| H25.032 | — |
| H25.033 | — |
| H25.041 | — |
| H25.042 | — |
| H25.043 | — |
| H25.11 | — |
| H25.12 | — |
| H25.13 | — |
| H25.21 | — |
| H25.22 | — |
| H25.23 | — |
| H25.811 | — |
| H25.812 | — |
| H25.813 | — |
| H25.89 | — |
| H25.9 | — |
| H26.001 | — |
Procedure codes: 76519, 92136.
Coverage indications, limitations and medical necessity
Abstract:
There are two methods used for intraocular lens power calculation:
• A-Scan Ultrasound Ophthalmic Biometry
Ophthalmic A-scan biometry by ultrasound echography is performed through the optical axis of the eye to determine the power of an intraocular (IOL) lens implant. The technical portion of ophthalmic biometry is usually performed in both eyes at the same setting.
• Non-Ultrasound Ophthalmic Biometry
Optical coherence biometry (OCB) utilizes partial coherence interferometry for measuring axial length (biometry) and for intraocular lens power calculation when planning for cataract surgery. OCB also measures the corneal curvature and anterior chamber depth. The technical portion is usually performed in both eyes at the same visit.
Indications:
A diagnostic ultrasound A-scan generally is used for patients who have simple cataracts. For patients with a dense cataract, an ultrasound B-scan may be used. (CMS Publication 100-03, Medicare National Coverage Determinations(NCD)Manual , Chapter 1, Part 1, Section 10.1 )
A second complete A scan/OCB will be covered if a different surgeon, unaffiliated with the surgeon who performed the first cataract extraction, performed the extraction on the second eye. We would not anticipate a high frequency of these instances.
Limitations:
Currently, the relative value units (RVUs) for the global and technical components of each method of ophthalmic biometry for intraocular lens power calculation are based on the procedure being bilaterally performed. If unilateral cataract extraction with an IOL implant is planned, a bilateral technical component of the A-scan or OCB is typically performed, while the professional component of the power calculation is performed unilaterally (on the operative eye only). Thus, the technical components are considered bilateral and the professional component is considered unilateral.
Prior to cataract surgery on the second, contralateral eye, allowance for the power calculation can be made. However, allowance for the technical component of the A-scan or OCB CPT code cannot be made since this bilateral procedure was performed and reimbursed at the time of the first surgery.
The technical component of the scan will generally provide valid information for twelve months. A repeat scan in less than twelve months would not be covered without documentation of significant change in vision (unless required because a second unaffiliated surgeon performed the second cataract extraction.) Generally, when bilateral cataracts are noted at examination, extraction of the second cataract is only performed after results of the first cataract extraction are known and symptoms or findings support the medical necessity for removal of the cataract in the other eye. If ophthalmic biometry is performed and later the surgery is canceled, it is reasonable to allow a repeat scan if significant time, e.g., greater than one (1) year, has elapsed when surgery is rescheduled.
Ophthalmic biometry for lens power calculation should not be performed unless a decision to remove the cataract has been made by the patient and surgeon. If the biometry is performed by an optometrist, he/she should do so in coordination with the operating surgeon so that only one procedure is necessary. If the biometry is repeated by the operating surgeon due to inadequacy of the study, the original eye care physician/provider should anticipate not being reimbursed for the study.
Summary of evidence (opening)
N/A
the full summary and analysis of evidence are in the CMS record.
Dates, lineage and related policies
- Original determination effective
- 2015-10-01
- Current revision effective
- 2026-04-01
- MCD version
- 16
- Derived from
- L26441
The contractor lists 3 National Coverage Determinations as related: NCD 220.5 Ultrasound Diagnostic Procedures, NCD 10.1 Use of Visual Tests Prior to and General Anesthesia during Cataract Surgery, NCD 80.10 Phaco-Emulsification Procedure - Cataract Extraction. Where an NCD speaks, it controls; the LCD can only address what the NCD leaves open.
Using this policy on a claim
Match the documented indication to the covered indications above before the service is scheduled, carry a diagnosis from the article's covered list on the claim line, and keep the elements the documentation section asks for in the record, because the contractor can request it later through medical review. A denial under this policy arrives as CARC 50 with remark N115; the LCD lookup guide walks through the appeal path and the Advance Beneficiary Notice rules, and the Wellpoint Federal hub lists every other active policy from the same contractor.
The same policy title at other contractors
Contractors often adopt each other's policies and then revise them separately, so the criteria and the diagnosis lists drift apart. The topic comparison lines up every version.
Frequently asked questions
What does LCD L33621 cover?
Ophthalmic A-scan biometry by ultrasound echography is performed through the optical axis of the eye to determine the power of an intraocular (IOL) lens implant. The technical portion of ophthalmic biometry is usually performed in both eyes at the same setting. The full indications and limitations are reproduced on this page from the CMS Medicare Coverage Database export of September 24, 2026.
Which states does LCD L33621 apply to?
Wellpoint Federal applies it to Medicare claims in CT, DN, IL, MA, ME, MN, NH, NY, QN, RI, UN, VT, WI. A Local Coverage Determination binds only the contractor that wrote it; the same service in another jurisdiction is judged under that contractor's own policy or, where none exists, claim by claim.
Which diagnosis codes support medical necessity under LCD L33621?
The companion billing and coding article A56549 lists 97 ICD-10-CM codes in 1 group that support medical necessity; the first 24 appear on this page and the complete list is in the article on cms.gov.
How do I appeal a denial under LCD L33621?
The remittance carries claim adjustment reason code 50 with remark code N115, naming the LCD. Compare the documented indication with the policy's covered indications and the article's diagnosis list, then file a redetermination within 120 days with the record attached; if the service genuinely falls outside the policy, the patient can be billed only when a valid Advance Beneficiary Notice was obtained before the service.
Sources
Every figure on this page is taken from the CMS publications below, as released by the Centers for Medicare & Medicaid Services. Projection built 2026-10-02. Verify against the primary file before billing or contracting decisions.
- Medicare Coverage Database, current LCD exportVersion MCD release 2026-09-24 · effective 2026-09-20 · file lcd.csvSHA-256 2fcc4251b6ddd1eb…
- Medicare Coverage Database, current Billing and Coding Articles exportVersion MCD release 2026-09-24 · effective 2026-09-20 · file article.csvSHA-256 f31932f1df3b4035…
- ICD-10-CM FY2027 code descriptionsVersion FY2027 · effective 2026-10-01 · file icd10cm_codes_2027.txtSHA-256 3c0583a38ee0e848…
Disclaimer
The policy text and code lists are reproduced from the CMS Medicare Coverage Database export as an operational reference. Verify against the current LCD and article on cms.gov before billing; coverage depends on the full record and the contractor. Not legal, clinical or billing advice.