Skip to main content

LCD L33583: Diagnostic and Therapeutic Esophagogastroduodenoscopy

LCD L33583, Diagnostic and Therapeutic Esophagogastroduodenoscopy, is the Local Coverage Determination that First Coast Service Options, Inc. applies to claims from 1 state plus 2 territories (FL, PR, VI), effective 2019-10-01 and first in force 2015-10-01. The policy text runs 928 words, and its billing and coding article A57063 lists 821 ICD-10-CM codes that support medical necessity for 21 procedure codes. No other contractor publishes a policy with this title.

Compiled from CMS files by the QuickIntell RCM Editorial Team · Data effective · Method: reference methodology · Report a data correction

Data currency: Medicare Coverage Database LCD export: MCD release November 12, 2026 (effective November 8, 2026); Medicare Coverage Database billing and coding articles: MCD release November 12, 2026 (effective November 8, 2026). Next CMS release: weekly, every Thursday.

Contractor
First Coast Service Options, Inc.
States and territories
3
FL PR VI
Revision effective
2019-10-01
Original effective
2015-10-01
Policy text
928 words
Covered ICD-10 codes (articles)
821

Where this LCD applies

Each contract number is a jurisdiction on the remittance; the policy binds claims processed under these contracts and no others.

Contracts that apply LCD L33583
ContractContractorTypeStates
09101First Coast Service Options, Inc.A and B MACFL
09201First Coast Service Options, Inc.A and B MACPR VI
09102First Coast Service Options, Inc.A and B MACFL
09202First Coast Service Options, Inc.A and B MACPR
09302First Coast Service Options, Inc.A and B MACVI

Billing and coding article A57063: diagnoses and procedure codes

Since 2019 the codes live in the companion article rather than the LCD. Billing and Coding A57063 (Billing and Coding: Diagnostic and Therapeutic Esophagogastroduodenoscopy) carries the diagnosis and procedure lists the contractor loads as the claims edit. CPT codes are shown as bare numbers because the descriptors are licensed by the AMA; HCPCS Level II descriptors are public and shown. Each article below opens its complete covered and non-covered ICD-10-CM lists, by group and with the contractor's group instructions, and the LCD code lookup answers whether one diagnosis is covered for one procedure code in a given state.

Coverage is only half of the claim edit: when two of the listed procedure codes are billed on the same date, test the pair against the NCCI edits before relying on both being paid.

A57063: Billing and Coding: Diagnostic and Therapeutic Esophagogastroduodenoscopy (Billing and Coding, effective 2026-10-01)

Covered ICD-10-CM codes
821
1 group
Non-covered ICD-10-CM codes
0
Procedure codes listed
21
Full article
cms.gov record
First 24 covered ICD-10-CM codes in A57063
ICD-10-CMDescription (FY2027)
B25.2Cytomegaloviral pancreatitis
B37.81Candidal esophagitis
C15.3Malignant neoplasm of upper third of esophagus
C15.4Malignant neoplasm of middle third of esophagus
C15.5Malignant neoplasm of lower third of esophagus
C15.8Malignant neoplasm of overlapping sites of esophagus
C15.9Malignant neoplasm of esophagus, unspecified
C16.0Malignant neoplasm of cardia
C16.1Malignant neoplasm of fundus of stomach
C16.2Malignant neoplasm of body of stomach
C16.3Malignant neoplasm of pyloric antrum
C16.4Malignant neoplasm of pylorus
C16.5Malignant neoplasm of lesser curvature of stomach, unspecified
C16.6Malignant neoplasm of greater curvature of stomach, unspecified
C16.8Malignant neoplasm of overlapping sites of stomach
C16.9Malignant neoplasm of stomach, unspecified
C17.0Malignant neoplasm of duodenum
C17.1Malignant neoplasm of jejunum
C17.2Malignant neoplasm of ileum
C17.3Meckel's diverticulum, malignant
C17.8Malignant neoplasm of overlapping sites of small intestine
C17.9Malignant neoplasm of small intestine, unspecified
C22.0Liver cell carcinoma
C22.2Hepatoblastoma

Procedure codes: 43233, 43235, 43236, 43237, 43238, 43239, 43241, 43243, 43244, 43245, 43246, 43247, 43248, 43249, 43250, 43251, 43253, 43254, 43255, 43266, 43270.

Coverage indications, limitations and medical necessity

History/Background and/or General Information

Upper intestinal endoscopy is performed with a lighted, flexible, fiberoptic instrument passed through the cricopharynx. The patient receives conscious sedation. A topical anesthetic is sometimes applied to the posterior pharynx. Direct visualization of the entire esophagus, stomach, and duodenum (to the junction of the second and third portions) can be accomplished easily with modern instruments that are less than 12mm in diameter. Esophagogastroduodenoscopy (EGD) is a technique utilized to examine, obtain samples, and in some instances, to treat pathological conditions.

Diagnostic observations are made concerning focal benign or malignant lesions, diffuse mucosal changes, luminal obstruction, motility, and extrinsic compression by contiguous structures. A diagnostic EGD allows the examiner to visualize abnormalities detectable by the technique and to photograph, biopsy, and/or remove lesions as appropriate.

The purpose of the therapeutic EGD is to manage hemorrhage; remove foreign bodies and neoplastic growths; to relieve obstruction due to stricture, malignancy, or other causes through dilatation or the placement of stents; and to assist in the placement of percutaneous gastrostomy tubes.

Covered Indications

EGD(s)will be considered medically reasonable and necessary under the following diagnostic conditions:

• Patient has upper abdominal distress (e.g., gastroesophageal reflux disease) which persists despite an appropriate trial of symptomatic therapy;

• Patient has upper abdominal distress associated with a short history of signs and symptoms suggesting significant associated disease or illness (e.g., weight loss, anorexia, vomiting, nonsteroidal anti-inflammatory drug [NSAID] intake, other gastric irritant intake);

• Patients over the age of 40 who have experienced a significant history of heartburn that returns after a course of symptomatic therapy;

• Patients who have dysphagia or odynophagia;

• Patient has persistent, unexplained vomiting;

• Patient has upper gastrointestinal x-ray findings of:

• any lesion that requires biopsy for diagnosis; or

• gastric ulcer suspicious of cancer; or

• evidence of stricture or obstruction;

• To assess acute injury after caustic agent ingestion;

• When anti-reflux surgery is contemplated; or

• Patient has gastrointestinal bleeding:

• in most actively bleeding patients; or

• for presumed chronic blood loss and iron deficiency anemia when investigation of large bowel is negative.

EGD(s) will be considered medically reasonable and necessary for the following therapeutic purposes:

• Treatment of bleeding lesions;

• Removal of foreign bodies;

• Sclerotherapy and/or band ligation for bleeding from esophageal or gastric varices;

• Dilatation of strictures in the upper intestinal tract;

• Removal of selected polypoid lesions;

• Placement of feeding tubes; or

• Palliative therapy of stenosing neoplasms (e.g., laser, stent placement).

Gastrointestinal bleeding may be treated with a variety of methods. Direct contact heater probes and hemostatic injections into or around the bleeding vessels are both effective therapy for acute bleeding.

Foreign body removal from the stomach or esophagus is usually successful with these flexible instruments. The foreign bodies can be retrieved by either of two methods. The first method is to capture the foreign body with a snare device/grasping forceps and pull the item out with the endoscope. The second method is accomplished by piecemeal destruction and pushing the bolus through the esophagus into the stomach.

Esophageal varices may be injected with a variety of sclerosing solutions. Eradication of varices requires, on the average, five sclerotherapy sessions, with multiple injections given during each session.

Dilatation of strictures may be accomplished with a balloon placed through the endoscope and inflated using hydrostatic pressure. Bougies are rubber dilators available in various sizes up to approximately 2.0cm. Plastic bougies and other dilating probes are usually passed over a guide wire. This procedure involves placing the guide wire into the stomach through the endoscope. The endoscope is then withdrawn leaving the guide wire in place. The dilating probes and plastic bougies are then passed over the guide wire. After the largest dilator is used, the dilator and guide wire are removed. Esophageal dilation is performed after a definitive diagnosis has been established in patients exhibiting dysphagia. The goal in most cases is a lumenal diameter of 16-17mm which allows passage of solid food. A series of dilators may be passed over the guide wire to reach the goal of therapy.

Follow-up EGD(s)will be considered medically reasonable and necessary for the following indications:

• Biopsy surveillance of patients with Barrett’s esophagus every 12 to 24 months. However, if dysplasia is present, earlier surveillance intervals of from three to six months may be required;

• Follow-up of gastric ulcers to healing or satisfaction that they are benign;

• Follow-up and treatment of esophageal strictures requiring guidewire dilation;

• Follow-up of duodenal ulcer or other lesions of the upper gastrointestinal tract that have resulted in serious consequences (e.g., hemorrhage);

• Follow-up of patients having a previous gastric polypectomy for adenoma; or

• Follow-up and treatment of patients with esophageal varices or bleeding lesions requiring recurrent therapy (e.g., esophageal varices, gastric varices, angiodysplastic or watermelon stomach lesions, radiation gastritis).

• Follow-up for removal of percutaneous gastrostomy tube (PEG)

Limitations

Periodic EGD is NOT usually indicated in the following situations:

• Surveillance of healed, benign disease such as gastric or duodenal ulcer or benign esophageal strictures; or

• Cancer surveillance in patients with pernicious anemia, treated achalasia, or prior gastric resection.

EGD is generally contraindicated for patients with recent myocardial infarction.

As published in the CMS IOM Publication 100-08, Medicare Program Integrity Manual , Chapter 13, Section 13.5.4, an item or service may be covered by a contractor LCD if it is reasonable and necessary under the Social Security Act Section 1862 (a)(1)(A). Contractors shall determine and describe the circumstances under which the item or service is considered reasonable and necessary.

Summary of evidence (opening)

N/A

The contractor cites 2 sources in the bibliography; the full summary and analysis of evidence are in the CMS record.

Dates, lineage and related policies

Original determination effective
2015-10-01
Current revision effective
2019-10-01
Last reviewed by the contractor
2018-08-08
MCD version
21
Derived from
L28823

The contractor lists 2 National Coverage Determinations as related: NCD 100.2 Endoscopy, NCD 100.3 24-Hour Ambulatory Esophageal pH Monitoring. Where an NCD speaks, it controls; the LCD can only address what the NCD leaves open.

Using this policy on a claim

Match the documented indication to the covered indications above before the service is scheduled, carry a diagnosis from the article's covered list on the claim line (the diagnosis coverage checker tests one code pair against every article that applies in a state), and keep the elements the documentation section asks for in the record, because the contractor can request it later through medical review. A denial under this policy arrives as CARC 50 with remark N115; the LCD lookup guide walks through the appeal path and the Advance Beneficiary Notice rules, and the First Coast Service Options, Inc. hub lists every other active policy from the same contractor.

For teams evaluating QuickIntell software

Where QuickIntell fits with this policy

If your team repeatedly reviews local coverage policies, explore QuickAuth for requirement checks, documentation and status tracking with staff oversight. Confirm the applicable policy, supported workflow and review responsibilities. Use QuickRCM to evaluate the separate claim and denial workflow.

Optional software evaluation, not payer support or help with an individual claim. For coverage or payment decisions, use the official sources on this page. Do not include patient information in a demo booking or inquiry.

Frequently asked questions

What does LCD L33583 cover?

Upper intestinal endoscopy is performed with a lighted, flexible, fiberoptic instrument passed through the cricopharynx. The patient receives conscious sedation. A topical anesthetic is sometimes applied to the posterior pharynx. Direct visualization of the entire esophagus, stomach, and duodenum (to the junction of the second and third portions) can be accomplished easily with modern instruments that are less… The full 928-word policy text is reproduced below from the Medicare Coverage Database export of November 12, 2026.

Which states does LCD L33583 apply to?

First Coast Service Options, Inc. applies it to Medicare claims in 1 state plus 2 territories: FL, PR, VI. It binds only that contractor; outside these jurisdictions the same service is judged under the local contractor's own policy or, where none exists, claim by claim.

Which diagnosis codes support medical necessity under LCD L33583?

The companion billing and coding article A57063 lists 821 ICD-10-CM codes in 1 group that support medical necessity; the first 24 appear on this page, where the complete list opens by group with the contractor's group instructions.

How do I appeal a denial under LCD L33583?

A denial under LCD L33583 carries claim adjustment reason code 50 with remark code N115. Compare the documented indication with the policy's covered indications and article A57063's 821 covered diagnosis codes, then file a redetermination with First Coast Service Options, Inc. within 120 days, record attached. If the service falls outside the policy, bill the patient only with a valid Advance Beneficiary Notice signed before the service.

Sources

Every figure on this page is taken from the CMS publications below, as released by the Centers for Medicare & Medicaid Services. Projection built 2026-11-16. Verify against the primary file before billing or contracting decisions. The reference methodology explains how each figure is computed from these files.

Disclaimer

The policy text and code lists are reproduced from the CMS Medicare Coverage Database export as an operational reference. Verify against the current LCD and article on cms.gov before billing; coverage depends on the full record and the contractor. Not legal, clinical or billing advice.

Found a figure that does not match the CMS file? Report a data correction with the CMS file and the value you expected; the request reaches the editorial team through the contact form.